{"id":8277,"date":"2025-11-04T16:04:12","date_gmt":"2025-11-04T16:04:12","guid":{"rendered":"https:\/\/kmslaser.com\/?p=8277"},"modified":"2026-01-29T02:24:18","modified_gmt":"2026-01-29T02:24:18","slug":"quelle-est-la-pression-maximale-par-impact-dune-machine-de-therapie-par-ondes-de-choc","status":"publish","type":"post","link":"https:\/\/kmslaser.com\/fr\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/","title":{"rendered":"Quelle est la pression maximale par impact d'un appareil de th\u00e9rapie par ondes de choc ?"},"content":{"rendered":"<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-modern-laboratory-scene-with-a-professional-engi.jpg\" alt=\"Ing\u00e9nieur testant les niveaux de pression d&#039;un appareil laser en laboratoire (ID#1)\" class=\"top-image-square\">\n<\/p>\n<p>Lorsque j'ai commenc\u00e9 \u00e0 tester la pression de sortie de nos premiers prototypes d'ondes de choc, j'ai \u00e9t\u00e9 choqu\u00e9 par la gamme : certains appareils produisaient des tapotements doux, tandis que d'autres produisaient des ondes de choc suffisamment puissantes pour briser les d\u00e9p\u00f4ts calcifi\u00e9s.  <\/p>\n<p><strong>La pression maximale par impact dans une machine de th\u00e9rapie par ondes de choc varie consid\u00e9rablement selon le type : les appareils \u00e0 ondes de choc focalis\u00e9es atteignent g\u00e9n\u00e9ralement des pressions de pointe de 10 \u00e0 100 MPa (et jusqu'\u00e0 150 MPa dans les syst\u00e8mes avanc\u00e9s), tandis que les machines \u00e0 ondes de choc radiales produisent des pressions plus faibles d'environ 0,1 \u00e0 1 MPa (environ 1 \u00e0 10 bars), la plupart des unit\u00e9s cliniques fonctionnant jusqu'\u00e0 5 bars. Ces niveaux de pression d\u00e9terminent directement la profondeur et la pr\u00e9cision avec lesquelles l'\u00e9nergie peut \u00eatre d\u00e9livr\u00e9e dans les tissus.<\/strong>  <\/p>\n<p>En tant que fabricant, nous v\u00e9rifions la pression de sortie de chaque mod\u00e8le avec des capteurs calibr\u00e9s, car m\u00eame de l\u00e9gers \u00e9carts peuvent modifier l'efficacit\u00e9 du traitement. Des normes ind\u00e9pendantes telles que <a href=\"https:\/\/webstore.iec.ch\/publication\/26171\">IEC 60601-2-62<\/a> <sup><a href=\"#footnote-1\" id=\"ref-1\">1<\/a><\/sup> d\u00e9finissent les exigences de test pour les appareils d'ultrasons th\u00e9rapeutiques et d'ondes de choc.<\/p>\n<hr \/>\n<h2>Pourquoi la pression de pointe est-elle essentielle pour d\u00e9terminer la profondeur et la focalisation de l'\u00e9nergie des ondes de choc ?<\/h2>\n<p>Lorsque je con\u00e7ois de nouvelles t\u00eates d'applicateur, l'une de mes principales pr\u00e9occupations est la mani\u00e8re dont la pression de pointe se traduit par une profondeur biologique. Plus la pression est \u00e9lev\u00e9e, plus l'\u00e9nergie devient profonde et concentr\u00e9e.  <\/p>\n<p><strong>La pression de pointe d\u00e9termine \u00e0 la fois la profondeur de p\u00e9n\u00e9tration et la concentration de l'\u00e9nergie au point focal : des pressions de pointe plus \u00e9lev\u00e9es (sup\u00e9rieures \u00e0 50 MPa) cr\u00e9ent des impulsions fortes et focalis\u00e9es id\u00e9ales pour les tissus profonds ou les os, tandis que des pressions plus faibles (inf\u00e9rieures \u00e0 1 MPa) produisent une diffusion d'\u00e9nergie plus large et moins profonde, adapt\u00e9e aux traitements des tissus mous.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2digital-illustration-showing-how-varying-peak-pres.jpg\" alt=\"Illustration montrant les effets de la pression de cr\u00eate sur les couches tissulaires (ID#2)\" title=\"Tableau de pression tissulaire\" \/><\/p>\n<p>Cette relation est bien d\u00e9crite dans <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/11729954\/\">les \u00e9tudes physiques de la propagation des ondes de choc<\/a> <sup><a href=\"#footnote-2\" id=\"ref-2\">2<\/a><\/sup>, qui montrent comment la densit\u00e9 d'\u00e9nergie augmente avec l'augmentation de la pression de pointe.<\/p>\n<h3>Comment la pression affecte la distribution de l'\u00e9nergie<\/h3>\n<table>\n<thead>\n<tr>\n<th>Pression maximale<\/th>\n<th>Typical Range<\/th>\n<th>Profondeur de p\u00e9n\u00e9tration<\/th>\n<th>Axe de traitement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Bas (0,1\u20131 MPa \/ 1\u201310 bar)<\/td>\n<td>Syst\u00e8mes radiaux<\/td>\n<td>0\u20134 cm<\/td>\n<td>Large, superficiel<\/td>\n<\/tr>\n<tr>\n<td>Moyen (5\u201350 MPa)<\/td>\n<td>ESWT focalis\u00e9e<\/td>\n<td>2\u20138 cm<\/td>\n<td>Contr\u00f4l\u00e9, mi-profondeur<\/td>\n<\/tr>\n<tr>\n<td>\u00c9lev\u00e9 (50\u2013150 MPa)<\/td>\n<td>Syst\u00e8mes \u00e9lectrohydrauliques \/ pi\u00e9zo\u00e9lectriques<\/td>\n<td>4\u201312 cm<\/td>\n<td>Profond, pr\u00e9cis<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Exemple concret<\/h3>\n<p>En pratique, les appareils \u00e0 haute pression permettent aux cliniciens de traiter des cas tenaces comme les pseudarthroses ou les tendinopathies calcifiantes. Par exemple, <a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S1876382023000595\">l'ESWT focalis\u00e9e pour les pseudarthroses<\/a> <sup><a href=\"#footnote-3\" id=\"ref-3\">3<\/a><\/sup> utilise des pressions sup\u00e9rieures \u00e0 50 MPa pour stimuler l'ost\u00e9ogen\u00e8se. Les syst\u00e8mes \u00e0 basse pression, en revanche, sont pr\u00e9f\u00e9r\u00e9s pour les l\u00e9sions des tissus mous et la gestion de la douleur, o\u00f9 le confort et la couverture sont prioritaires.  <\/p>\n<p>Lorsque nous r\u00e9glons nos syst\u00e8mes, nous visons toujours une mont\u00e9e en pression douce pour r\u00e9duire l'inconfort du patient tout en maintenant l'efficacit\u00e9 th\u00e9rapeutique.<\/p>\n<hr \/>\n<h2>Quelles sont les valeurs de pression maximale courantes (bar ou MPa) pour les appareils \u00e0 ondes de choc radiales ?<\/h2>\n<p>Je dis souvent aux clients que \u201c radial \u201d ne signifie pas faible, cela signifie simplement que l'\u00e9nergie se propage plus largement. Cependant, la plage de pression est beaucoup plus faible par rapport aux syst\u00e8mes focalis\u00e9s.  <\/p>\n<p><strong>Les appareils d'ondes de choc radiales atteignent g\u00e9n\u00e9ralement des pressions maximales entre 1 bar et 10 bar (\u2248 0,1\u20131 MPa), la plupart des syst\u00e8mes de qualit\u00e9 clinique fonctionnant jusqu'\u00e0 5 bar (\u2248 0,5 MPa). Ces appareils sont entra\u00een\u00e9s pneumatiquement, utilisant de l'air comprim\u00e9 pour acc\u00e9l\u00e9rer un projectile qui frappe un applicateur m\u00e9tallique.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/3cutaway-3d-render-of-a-pneumatic-handpiece-showing.jpg\" alt=\"Vue en coupe du m\u00e9canisme de la pi\u00e8ce \u00e0 main de th\u00e9rapie par ondes de choc (ID#3)\" title=\"Conception de l&#039;appareil \u00e0 ondes de choc\" \/><\/p>\n<p>Les <a href=\"https:\/\/journals.sagepub.com\/doi\/full\/10.1177\/03093646221078311\">conception m\u00e9canique des pi\u00e8ces \u00e0 main pneumatiques<\/a> <sup><a href=\"#footnote-4\" id=\"ref-4\">4<\/a><\/sup> d\u00e9termine directement la constance de la production de pression radiale.  <\/p>\n<h3>Plages de pression radiales typiques<\/h3>\n<table>\n<thead>\n<tr>\n<th>R\u00e9glage<\/th>\n<th>Pression (bar)<\/th>\n<th>Pression (MPa)<\/th>\n<th>Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Faible<\/td>\n<td>1\u20132 bar<\/td>\n<td>0,1\u20130,2 MPa<\/td>\n<td>Points g\u00e2chettes, rel\u00e2chement fascial<\/td>\n<\/tr>\n<tr>\n<td>Moyen<\/td>\n<td>3\u20134 bar<\/td>\n<td>0,3\u20130,4 MPa<\/td>\n<td>Th\u00e9rapie des tendons et des ligaments<\/td>\n<\/tr>\n<tr>\n<td>Haut<\/td>\n<td>5 bar<\/td>\n<td>0,5 MPa<\/td>\n<td>D\u00e9p\u00f4ts calcifi\u00e9s, douleur chronique<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Aper\u00e7us d'utilisation clinique<\/h3>\n<p>\u00c0 1\u20132 bar, les traitements sont doux et utilis\u00e9s pour les zones sensibles. Autour de 4\u20135 bar, l'impact est plus fort, stimulant la circulation sanguine et le remodelage des tissus. <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC7275282\/\">Aper\u00e7us cliniques de la TECR radiale<\/a> <sup><a href=\"#footnote-5\" id=\"ref-5\">5<\/a><\/sup> confirment son efficacit\u00e9 pour les affections tendineuses et fasciales. De nombreuses pi\u00e8ces \u00e0 main modernes peuvent supporter 2 millions de chocs m\u00eame \u00e0 5 bar, mais elles n\u00e9cessitent une ing\u00e9nierie pr\u00e9cise pour maintenir la durabilit\u00e9 et une sortie constante.  <\/p>\n<p>Cet \u00e9quilibre entre pression et conception m\u00e9canique d\u00e9finit la fiabilit\u00e9 globale d'un syst\u00e8me radial.<\/p>\n<hr \/>\n<h2>Pour les appareils \u00e0 ondes de choc focalis\u00e9es, quelles pressions de pointe sont r\u00e9alisables ?<\/h2>\n<p>Lorsque j'ai mesur\u00e9 pour la premi\u00e8re fois les ondes de choc focalis\u00e9es g\u00e9n\u00e9r\u00e9es par un syst\u00e8me \u00e9lectrohydraulique, la lecture du capteur a d\u00e9pass\u00e9 100 MPa. C'est la v\u00e9ritable puissance de la technologie focalis\u00e9e.  <\/p>\n<p><strong>Les appareils de th\u00e9rapie par ondes de choc focalis\u00e9es atteignent g\u00e9n\u00e9ralement des pressions positives maximales entre 10 MPa et 100 MPa, en fonction de la m\u00e9thode de g\u00e9n\u00e9ration (\u00e9lectrohydraulique, \u00e9lectromagn\u00e9tique ou pi\u00e9zo\u00e9lectrique). Certains syst\u00e8mes avanc\u00e9s peuvent atteindre jusqu'\u00e0 150 MPa pour des applications sur tissus profonds ou durs.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/4photorealistic-image-of-a-focused-shockwave-handpi.jpg\" alt=\"Technicien tenant la pi\u00e8ce \u00e0 main de th\u00e9rapie par ondes de choc lors d&#039;un test de fonctionnement (ID#4)\" title=\"Test des ondes de choc\" \/><\/p>\n<p>Selon <a href=\"https:\/\/link.springer.com\/article\/10.1007\/s00167-020-06147-z\">des \u00e9tudes comparatives des types de g\u00e9n\u00e9ration de TECS<\/a> <sup><a href=\"#footnote-6\" id=\"ref-6\">6<\/a><\/sup>, les syst\u00e8mes \u00e9lectrohydrauliques d\u00e9livrent la pression et la p\u00e9n\u00e9tration les plus \u00e9lev\u00e9es.  <\/p>\n<p>Nous validons chaque applicateur focalis\u00e9 dans notre laboratoire avec <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/23494629\/\">des techniques de cartographie de pression par hydrophone<\/a> <sup><a href=\"#footnote-7\" id=\"ref-7\">7<\/a><\/sup> pour confirmer les valeurs r\u00e9elles de pression maximale et assurer une sortie constante sur toute la plage de traitement.<\/p>\n<hr \/>\n<h2>Comment un acheteur peut-il valider la pression maximale revendiqu\u00e9e avant d'acheter ?<\/h2>\n<p>J'ai vu trop de fiches techniques indiquer des chiffres de pression irr\u00e9alistes sans tests appropri\u00e9s. Les acheteurs devraient toujours demander des preuves.  <\/p>\n<p><strong>Pour valider la pression maximale revendiqu\u00e9e, les acheteurs devraient demander des certificats de calibration, des rapports de test bas\u00e9s sur hydrophone ou capteur, et des donn\u00e9es de v\u00e9rification par des tiers qui confirment la sortie r\u00e9elle dans des conditions d'exploitation cliniques. Les fabricants fiables fourniront des unit\u00e9s claires (bar ou MPa) et expliqueront leur m\u00e9thodologie de mesure.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/53d-visualization-of-a-hydrophone-test-setup-measur.jpg\" alt=\"Installation d&#039;\u00e9talonnage de la pression d&#039;un appareil \u00e0 ultrasons \u00e0 cavitation en laboratoire (ID#5)\" title=\"\u00c9talonnage des ultrasons\" \/><\/p>\n<p>Une v\u00e9rification appropri\u00e9e suit la m\u00eame m\u00e9thodologie que les <a href=\"https:\/\/www.iso.org\/standard\/75628.html\">proc\u00e9dures d'\u00e9talonnage de la norme CEI<\/a> <sup><a href=\"#footnote-8\" id=\"ref-8\">8<\/a><\/sup> pour les dispositifs acoustiques m\u00e9dicaux. Les valeurs de pression peuvent \u00e9galement \u00eatre compar\u00e9es \u00e0 l'aide de <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/28554725\/\">protocoles de mesure de cavitation acoustique<\/a> <sup><a href=\"#footnote-9\" id=\"ref-9\">9<\/a><\/sup> pour \u00e9valuer la reproductibilit\u00e9.  <\/p>\n<p>En tant que fabricant, nous maintenons des bancs d'\u00e9talonnage internes et \u00e9mettons des rapports avec chaque exp\u00e9dition, car des donn\u00e9es transparentes renforcent la confiance \u00e0 long terme.<\/p>\n<hr \/>\n<h2>Conclusion<\/h2>\n<p>La pression de cr\u00eate d\u00e9finit la profondeur et l'efficacit\u00e9 du fonctionnement d'une machine \u00e0 ondes de choc. Une sortie de pression pr\u00e9cise et v\u00e9rifiable garantit \u00e0 la fois un traitement s\u00fbr et des performances fiables, principes fondamentaux derri\u00e8re chaque appareil que nous fabriquons. Pour r\u00e9f\u00e9rence suppl\u00e9mentaire, voir les <a href=\"https:\/\/shockwavetherapy.org\/about-ismst\/\">ressources techniques de la Soci\u00e9t\u00e9 internationale pour le traitement par ondes de choc m\u00e9dicales<\/a> <sup><a href=\"#footnote-10\" id=\"ref-10\">10<\/a><\/sup>.<\/p>\n<hr \/>\n<h2>Notes de bas de page<\/h2>\n<p><span id=\"footnote-1\">1. La norme CEI 60601-2-62 d\u00e9crit la s\u00e9curit\u00e9 des dispositifs th\u00e9rapeutiques \u00e0 ondes de choc. <a href=\"#ref-1\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-2\">2. \u00c9tude sur la pression et la distribution d'\u00e9nergie des ondes de choc dans les milieux biologiques. <a href=\"#ref-2\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-3\">3. Recherche d\u00e9montrant les effets des ESWT \u00e0 haute pression sur la r\u00e9g\u00e9n\u00e9ration osseuse. <a href=\"#ref-3\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-4\">4. Article analysant la m\u00e9canique et la fiabilit\u00e9 des pi\u00e8ces \u00e0 main pneumatiques. <a href=\"#ref-4\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-5\">5. Revue clinique confirmant l'efficacit\u00e9 des ESWT radiales pour les tendinopathies. <a href=\"#ref-5\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-6\">6. Aper\u00e7u comparatif des syst\u00e8mes ESWT \u00e9lectrohydrauliques, \u00e9lectromagn\u00e9tiques et pi\u00e9zo\u00e9lectriques. <a href=\"#ref-6\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-7\">7. M\u00e9thode de mesure de la pression de cr\u00eate dans les dispositifs de th\u00e9rapie par ondes de choc focalis\u00e9es. <a href=\"#ref-7\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-8\">8. Norme d'\u00e9talonnage ISO pour la mesure de la sortie acoustique dans les dispositifs m\u00e9dicaux. <a href=\"#ref-8\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-9\">9. Recherche sur les m\u00e9triques de cavitation utilis\u00e9es pour v\u00e9rifier les niveaux de pression acoustique. <a href=\"#ref-9\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-10\">10. Organisation proposant des directives internationales pour les param\u00e8tres et la s\u00e9curit\u00e9 de l'ESWT. <a href=\"#ref-10\">\ufe0e<\/a><\/span>  <\/p>","protected":false},"excerpt":{"rendered":"<p>When I first began testing the pressure output of our early shockwave prototypes, I was shocked by the range\u2014some devices generated gentle taps, while others produced shockwaves strong enough to break calcific deposits. The maximum pressure per impact in a shockwave therapy machine varies widely by type: focused shockwave devices typically reach peak pressures of [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":8278,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[60],"tags":[],"class_list":["post-8277","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-shockwave-therapy-machine"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine? - KMSLaser<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kmslaser.com\/fr\/quelle-est-la-pression-maximale-par-impact-dune-machine-de-therapie-par-ondes-de-choc\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine?\" \/>\n<meta property=\"og:description\" content=\"When I first began testing the pressure output of our early shockwave prototypes, I was shocked by the range\u2014some devices generated gentle taps, while others produced shockwaves strong enough to break calcific deposits. The maximum pressure per impact in a shockwave therapy machine varies widely by type: focused shockwave devices typically reach peak pressures of [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kmslaser.com\/fr\/quelle-est-la-pression-maximale-par-impact-dune-machine-de-therapie-par-ondes-de-choc\/\" \/>\n<meta property=\"og:site_name\" content=\"KMSLaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-04T16:04:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-29T02:24:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-modern-laboratory-scene-with-a-professional-engi.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sophia Wu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sophia Wu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/\"},\"author\":{\"name\":\"Sophia Wu\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\"},\"headline\":\"What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine?\",\"datePublished\":\"2025-11-04T16:04:12+00:00\",\"dateModified\":\"2026-01-29T02:24:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/\"},\"wordCount\":939,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/1a-modern-laboratory-scene-with-a-professional-engi.jpg\",\"articleSection\":[\"Shockwave Therapy Machine\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/\",\"name\":\"What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine? - KMSLaser\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/1a-modern-laboratory-scene-with-a-professional-engi.jpg\",\"datePublished\":\"2025-11-04T16:04:12+00:00\",\"dateModified\":\"2026-01-29T02:24:18+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#primaryimage\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/1a-modern-laboratory-scene-with-a-professional-engi.jpg\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/1a-modern-laboratory-scene-with-a-professional-engi.jpg\",\"width\":600,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/kmslaser.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"name\":\"KMSLaser\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/kmslaser.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\",\"name\":\"KMSLaser\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"width\":180,\"height\":71,\"caption\":\"KMSLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\",\"name\":\"Sophia Wu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"caption\":\"Sophia Wu\"},\"url\":\"https:\\\/\\\/kmslaser.com\\\/fr\\\/author\\\/sophia\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Quelle est la pression maximale par impact d'une machine de th\u00e9rapie par ondes de choc ? - KMSLaser","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kmslaser.com\/fr\/quelle-est-la-pression-maximale-par-impact-dune-machine-de-therapie-par-ondes-de-choc\/","og_locale":"fr_FR","og_type":"article","og_title":"What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine?","og_description":"When I first began testing the pressure output of our early shockwave prototypes, I was shocked by the range\u2014some devices generated gentle taps, while others produced shockwaves strong enough to break calcific deposits. The maximum pressure per impact in a shockwave therapy machine varies widely by type: focused shockwave devices typically reach peak pressures of [&hellip;]","og_url":"https:\/\/kmslaser.com\/fr\/quelle-est-la-pression-maximale-par-impact-dune-machine-de-therapie-par-ondes-de-choc\/","og_site_name":"KMSLaser","article_published_time":"2025-11-04T16:04:12+00:00","article_modified_time":"2026-01-29T02:24:18+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-modern-laboratory-scene-with-a-professional-engi.jpg","type":"image\/jpeg"}],"author":"Sophia Wu","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Sophia Wu","Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#article","isPartOf":{"@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/"},"author":{"name":"Sophia Wu","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588"},"headline":"What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine?","datePublished":"2025-11-04T16:04:12+00:00","dateModified":"2026-01-29T02:24:18+00:00","mainEntityOfPage":{"@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/"},"wordCount":939,"commentCount":0,"publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"image":{"@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-modern-laboratory-scene-with-a-professional-engi.jpg","articleSection":["Shockwave Therapy Machine"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/","url":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/","name":"Quelle est la pression maximale par impact d'une machine de th\u00e9rapie par ondes de choc ? - KMSLaser","isPartOf":{"@id":"https:\/\/kmslaser.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#primaryimage"},"image":{"@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-modern-laboratory-scene-with-a-professional-engi.jpg","datePublished":"2025-11-04T16:04:12+00:00","dateModified":"2026-01-29T02:24:18+00:00","breadcrumb":{"@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#primaryimage","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-modern-laboratory-scene-with-a-professional-engi.jpg","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-modern-laboratory-scene-with-a-professional-engi.jpg","width":600,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/kmslaser.com\/what-is-the-maximum-pressure-per-impact-of-a-shockwave-therapy-machine\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/kmslaser.com\/"},{"@type":"ListItem","position":2,"name":"What Is the Maximum Pressure per Impact of a Shockwave Therapy Machine?"}]},{"@type":"WebSite","@id":"https:\/\/kmslaser.com\/#website","url":"https:\/\/kmslaser.com\/","name":"KMSLaser","description":"","publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kmslaser.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/kmslaser.com\/#organization","name":"KMSLaser","url":"https:\/\/kmslaser.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","width":180,"height":71,"caption":"KMSLaser"},"image":{"@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588","name":"Sophia Wu","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","caption":"Sophia Wu"},"url":"https:\/\/kmslaser.com\/fr\/author\/sophia\/"}]}},"_links":{"self":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/posts\/8277","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/comments?post=8277"}],"version-history":[{"count":0,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/posts\/8277\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/media\/8278"}],"wp:attachment":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/media?parent=8277"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/categories?post=8277"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/tags?post=8277"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}