{"id":8070,"date":"2025-10-05T12:23:30","date_gmt":"2025-10-05T12:23:30","guid":{"rendered":"https:\/\/kmslaser.com\/?p=8070"},"modified":"2025-10-05T12:23:30","modified_gmt":"2025-10-05T12:23:30","slug":"machine-de-therapie-par-ondes-de-choc-puissance-quelle-est-la-puissance-typique-quelle-est-la-puissance-sure-et-comment-comparer-les-marques","status":"publish","type":"post","link":"https:\/\/kmslaser.com\/fr\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/","title":{"rendered":"Puissance de la machine de th\u00e9rapie par ondes de choc : qu'est-ce qui est typique, qu'est-ce qui est s\u00fbr, et comment comparer les marques ?"},"content":{"rendered":"<p><iframe data-testid=\"embed-iframe\" style=\"border-radius:12px\" src=\"https:\/\/open.spotify.com\/embed\/episode\/0iH0ZjZpXrZhxm7ff2zDG3?utm_source=generator&amp;theme=0\" width=\"100%\" height=\"152\" frameborder=\"0\" allowfullscreen=\"\" allow=\"autoplay; clipboard-write; encrypted-media; fullscreen; picture-in-picture\" loading=\"lazy\"><\/iframe><\/p>\n<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/1-a-professional-medical-equipment-trade-show-booth-.jpg\" alt=\"Rang\u00e9e de machines de beaut\u00e9 avanc\u00e9es lors d&#039;une exposition (ID#1)\" class=\"top-image-square\">\n<\/p>\n<p>J'entends souvent : \u201c Quelle est la puissance r\u00e9elle de cet appareil \u00e0 ondes de choc ? \u201d Je comprends pourquoi cela vous inqui\u00e8te. Les sp\u00e9cifications semblent confuses, le discours commercial semble vague et les protocoles varient.<\/p>\n<p><strong>R\u00e9ponse courte : la plupart de la \u201c puissance \u201d clinique s'exprime mieux en <a href=\"https:\/\/www.sciencedirect.com\/topics\/medicine-and-dentistry\/energy-flux-density\">Transducer Testing Details<\/a> <sup><a href=\"#footnote-1\" id=\"ref-1\">1<\/a><\/sup> pour l'ESWT focalis\u00e9e, et <a href=\"https:\/\/www.ismst.com\/ismst-protocols\/\">pression (bar)<\/a> <sup><a href=\"#footnote-2\" id=\"ref-2\">2<\/a><\/sup> pour les appareils \u00e0 ondes radiales\/de pression. La DFE th\u00e9rapeutique typique se situe autour de 0,10\u20130,30 mJ\/mm\u00b2 (focalis\u00e9e), tandis que les appareils radiaux sont couramment utilis\u00e9s en dessous de ~2,6 bar, m\u00eame si beaucoup atteignent 5 bar.<\/strong><\/p>\n<p>Je garderai un langage simple et des comparaisons \u00e9quitables. Je vous montrerai \u00e9galement comment comparer les marques c\u00f4te \u00e0 c\u00f4te afin que vous puissiez faire un choix clair pour votre protocole et votre march\u00e9.<\/p>\n<h2>Quelle est la \u201c puissance \u201d typique d'une machine de th\u00e9rapie par ondes de choc ?<\/h2>\n<p>Je sais que le terme \u201c puissance \u201d semble flou. J'ai assist\u00e9 \u00e0 des d\u00e9monstrations o\u00f9 un repr\u00e9sentant dit \u201c bars \u201d, un autre dit \u201c mJ\/mm\u00b2 \u201d et un troisi\u00e8me parle de \u201c watts \u201d.\u201d<\/p>\n<p><strong>Voici l'essentiel : la \u201c puissance \u201d n'est pas un seul chiffre. <a href=\"https:\/\/www.physio-pedia.com\/Extracorporeal_Shockwave_Therapy\">ESWT focalis\u00e9e<\/a> <sup><a href=\"#footnote-3\" id=\"ref-3\">3<\/a><\/sup> est g\u00e9n\u00e9ralement rapport\u00e9e comme densit\u00e9 de flux d'\u00e9nergie (mJ\/mm\u00b2). Les syst\u00e8mes radiaux s'appuient sur la pression (bar). Les bandes cliniques typiques sont d'environ 0,10\u20130,30 mJ\/mm\u00b2 pour l'ESWT focalis\u00e9e et d'environ 1\u20133 bar pour les syst\u00e8mes radiaux, bien que les appareils puissent atteindre des valeurs plus \u00e9lev\u00e9es.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/2-an-image-of-a-medical-trainer-presenting-a-slide-s.jpg\" alt=\"Professionnel m\u00e9dical donnant une pr\u00e9sentation technique (ID#2)\" title=\"Session de formation\" \/><\/p>\n<h3>Pourquoi les mots diff\u00e8rent<\/h3>\n<p>L'ESWT focalis\u00e9e produit une v\u00e9ritable onde de choc avec une petite zone focale et un temps de mont\u00e9e tr\u00e8s rapide, nous utilisons donc la DFE en mJ\/mm\u00b2. Les appareils radiaux cr\u00e9ent des ondes de pression qui se propagent vers l'ext\u00e9rieur ; les fabricants indiquent la pression (bar) et la fr\u00e9quence (Hz). Le <a href=\"https:\/\/www.ismst.com\/\">Soci\u00e9t\u00e9 Internationale pour le Traitement par Ondes de Choc M\u00e9dicales (ISMST)<\/a> <sup><a href=\"#footnote-4\" id=\"ref-4\">4<\/a><\/sup> encourage une terminologie standardis\u00e9e et un rapport complet des param\u00e8tres (type d'appareil, impulsions, EFD\/pression, fr\u00e9quence).<\/p>\n<h3>Plages typiques que vous verrez r\u00e9ellement<\/h3>\n<p>Les appareils focalis\u00e9s utilis\u00e9s pour les affections musculo-squelettiques fonctionnent couramment \u00e0 environ 0,10\u20130,30 mJ\/mm\u00b2, certaines plateformes permettant jusqu'\u00e0 environ 0,55 mJ\/mm\u00b2. Les appareils radiaux indiquent souvent 1 \u00e0 5 bars maximum, mais de nombreuses cliniques restent en dessous d'environ 2,6 bars pour le confort et la s\u00e9curit\u00e9.<\/p>\n<hr \/>\n<h2>Comment la puissance de la machine affecte-t-elle les r\u00e9sultats du traitement ?<\/h2>\n<p>J'ai vu des cliniques rechercher \u201cplus de puissance\u201d lorsque les r\u00e9sultats ralentissent. Je comprends l'envie. Mais les r\u00e9sultats ne s'am\u00e9liorent pas en tournant un seul bouton au maximum.<\/p>\n<p><strong>En r\u00e9sum\u00e9 : les r\u00e9sultats suivent la bonne dose au bon tissu plut\u00f4t que le plus grand chiffre accrocheur. Une EFD plus \u00e9lev\u00e9e peut aider dans certaines indications, mais trop peut augmenter la douleur et le risque. La pression radiale semble plus forte pour les patients \u00e0 des bars plus \u00e9lev\u00e9s, pourtant les preuves soutiennent des r\u00e9glages mod\u00e9r\u00e9s avec une technique correcte.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/3-an-advanced-digital-medical-render-showing-focused.jpg\" alt=\"Illustration 3D de la douleur au genou (ID#3)\" title=\"Focus sur la douleur articulaire\" \/><\/p>\n<h3>Ce que la litt\u00e9rature sugg\u00e8re (en langage clair)<\/h3>\n<p>Des \u00e9tudes et <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC6914804\/\">directives cliniques<\/a> <sup><a href=\"#footnote-5\" id=\"ref-5\">5<\/a><\/sup> divisent la TECS par bandes d'\u00e9nergie. Certains essais sur la tendinopathie calcifiante de l'\u00e9paule montrent de meilleurs effets \u00e0 \u22650,28 mJ\/mm\u00b2 par rapport \u00e0 une EFD plus faible, tandis que de nombreux protocoles sur tissus mous r\u00e9ussissent dans des bandes faibles \u00e0 mod\u00e9r\u00e9es. La TECS focalis\u00e9e peut cr\u00e9er un stress focal pr\u00e9cis pour stimuler la r\u00e9paration tissulaire. Les ondes radiales diffusent l'\u00e9nergie sur une plus grande surface et peuvent sembler intenses sans ajouter de dose focale.<\/p>\n<hr \/>\n<h2>Quelle est la plage de puissance s\u00fbre pour les utilisateurs ?<\/h2>\n<p>J'ai rencontr\u00e9 des cliniciens qui craignent le surtraitement. Je partage cette pr\u00e9occupation. La s\u00e9curit\u00e9 est la premi\u00e8re case \u00e0 cocher avant toute commande.<\/p>\n<p><strong>S\u00e9curit\u00e9 en pratique : utilisez des plages \u00e9tudi\u00e9es cliniquement, augmentez lentement et suivez les directives de l'ISMST\/de l'appareil. Pour la TECS focalis\u00e9e, de nombreux protocoles musculo-squelettiques se situent dans des EFD faibles \u00e0 mod\u00e9r\u00e9es ; pour la TECS radiale, de nombreuses cliniques maintiennent \u2264 environ 2,6 bars m\u00eame si l'appareil permet 5 bars. V\u00e9rifiez les contre-indications.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/4-close-up-photo-realistic-render-of-a-device-manual.jpg\" alt=\"Manuel d&#039;instructions avec kit de formation et stylo (ID#4)\" title=\"Mat\u00e9riel de formation\" \/><\/p>\n<p><a href=\"https:\/\/chattanoogarehab.com\/products\/intelect-radial-pressure-wave\">Manuels d'utilisation<\/a> <sup><a href=\"#footnote-6\" id=\"ref-6\">6<\/a><\/sup> recommandent des points de d\u00e9part conservateurs. Par exemple, un syst\u00e8me focalis\u00e9 comme le Chattanooga Intelect Focus indique 0,01\u20130,55 mJ\/mm\u00b2 et recommande de commencer \u00e0 environ 0,10 mJ\/mm\u00b2 avec un ajustement progressif.<\/p>\n<hr \/>\n<h2>Les r\u00e9glages de puissance r\u00e9glables sont-ils disponibles ?<\/h2>\n<p>Oui. Les appareils modernes vous permettent d'ajuster l'\u00e9nergie\/pression, la fr\u00e9quence, les impulsions et les applicateurs\/supports. Les unit\u00e9s focalis\u00e9es offrent couramment 0,01\u20130,55 mJ\/mm\u00b2 et 1\u20138 Hz ; les syst\u00e8mes radiaux permettent souvent 1\u20135 bars et 4\u201320 Hz, avec des \u00e9metteurs interchangeables qui modifient la sensation et la profondeur.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/5-close-up-view-of-a-therapist-adjusting-the-bar-pre.jpg\" alt=\"Technicien ajustant un appareil de th\u00e9rapie moderne (ID#5)\" title=\"\u00c9talonnage de l&#039;appareil\" \/><\/p>\n<p><a href=\"https:\/\/shockwavetherapy.org\/training\/\">Ressources de formation clinique<\/a> <sup><a href=\"#footnote-7\" id=\"ref-7\">7<\/a><\/sup> soulignent le r\u00e9glage correct des param\u00e8tres pour correspondre \u00e0 la tol\u00e9rance tissulaire et \u00e0 l'indication, plut\u00f4t que de rechercher les chiffres maximums.<\/p>\n<hr \/>\n<h2>Comment comparer les niveaux de puissance entre les marques ?<\/h2>\n<p>J'ai compar\u00e9 des dizaines de fiches techniques pour les acheteurs. L'astuce consiste \u00e0 normaliser les diff\u00e9rentes unit\u00e9s afin de pouvoir comparer la dose cible, et pas seulement le marketing.<\/p>\n<p><strong>Utilisez un cadre simple : s\u00e9parez d'abord les focalis\u00e9es des radiales. Ensuite, alignez les unit\u00e9s de dose (EFD vs bar), la fr\u00e9quence, la capacit\u00e9 d'impulsion et le contr\u00f4le de la profondeur. Enfin, confirmez les plages publi\u00e9es et <a href=\"https:\/\/www.shockwavetherapy.org\/about-eswt\/protocols\/\">les directives de protocole<\/a> <sup><a href=\"#footnote-8\" id=\"ref-8\">8<\/a><\/sup> provenant de sources reconnues (ISMST, manuels d'appareils).<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/6-infographic-layout-of-a-buyer-s-checklist-with-ico.jpg\" alt=\"Mat\u00e9riel de s\u00e9lection de machine de th\u00e9rapie par ondes de choc avec options de plage de dose et de profondeur\" title=\"Tableau des ondes de choc\" \/><\/p>\n<p>Lors de la comparaison, il est utile de consulter <a href=\"https:\/\/www.cochranelibrary.com\/cdsr\/doi\/10.1002\/14651858.CD003219.pub2\/full\">les revues de preuves cliniques<\/a> <sup><a href=\"#footnote-9\" id=\"ref-9\">9<\/a><\/sup> pour voir quelles bandes de dose sont r\u00e9ellement prises en charge, plut\u00f4t que de se fier uniquement aux valeurs maximales indiqu\u00e9es dans les brochures.<\/p>\n<hr \/>\n<h2>Conclusion<\/h2>\n<p>Utilisez la bonne unit\u00e9 pour la bonne technologie. Faites correspondre la dose aux tissus. Standardisez les param\u00e8tres. Comparez les marques par leurs plages, pas par leurs slogans. Pour l'approvisionnement, des ressources telles que <a href=\"https:\/\/www.fda.gov\/medical-devices\/buying-medical-devices\">les guides d'achat de dispositifs m\u00e9dicaux<\/a> <sup><a href=\"#footnote-10\" id=\"ref-10\">10<\/a><\/sup> garantissent des choix \u00e9clair\u00e9s et s\u00fbrs.<\/p>\n<hr \/>\n<h2>Notes de bas de page<\/h2>\n<p><span id=\"footnote-1\">1. Explication de la densit\u00e9 de flux d'\u00e9nergie en th\u00e9rapie par ondes de choc. <a href=\"#ref-1\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-2\">2. Protocoles ISMST d\u00e9crivant les unit\u00e9s de pression des ondes de choc radiales. <a href=\"#ref-2\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-3\">3. Aper\u00e7u des principes et de l'utilisation clinique de l'ESWT focalis\u00e9e. <a href=\"#ref-3\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-4\">4. Site officiel de l'ISMST pour la terminologie et les normes. <a href=\"#ref-4\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-5\">5. Revue des directives cliniques de l'ESWT pour les troubles musculo-squelettiques. <a href=\"#ref-5\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-6\">6. Manuel de l'appareil Chattanooga Intelect avec des recommandations de dosage. <a href=\"#ref-6\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-7\">7. Ressources de formation pour l'ajustement des appareils de th\u00e9rapie par ondes de choc. <a href=\"#ref-7\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-8\">8. Protocoles cliniques recommand\u00e9s par l'ISMST pour l'ESWT. <a href=\"#ref-8\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-9\">9. Revue de preuves Cochrane sur l'efficacit\u00e9 de la th\u00e9rapie par ondes de choc. <a href=\"#ref-9\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-10\">10. Guide de la FDA pour l'achat d'appareils m\u00e9dicaux s\u00fbrs. <a href=\"#ref-10\">\ufe0e<\/a><\/span>  <\/p>","protected":false},"excerpt":{"rendered":"<p>I often hear, \u201cWhat\u2019s the real power on this shockwave unit?\u201d I get why that worries you. Specs look confusing, sales talk sounds vague, and protocols vary. Short answer: most clinical \u201cpower\u201d is best expressed as energy flux density (EFD) 1 for focused ESWT, and pressure (bar) 2 for radial\/pressure-wave devices. Typical therapeutic EFD sits [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":8071,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[60],"tags":[],"class_list":["post-8070","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-shockwave-therapy-machine"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.1.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Shockwave Therapy Machine Power: what\u2019s typical, what\u2019s safe, and how do you compare brands? - KMSLaser<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kmslaser.com\/fr\/machine-de-therapie-par-ondes-de-choc-puissance-quelle-est-la-puissance-typique-quelle-est-la-puissance-sure-et-comment-comparer-les-marques\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Shockwave Therapy Machine Power: what\u2019s typical, what\u2019s safe, and how do you compare brands?\" \/>\n<meta property=\"og:description\" content=\"I often hear, \u201cWhat\u2019s the real power on this shockwave unit?\u201d I get why that worries you. Specs look confusing, sales talk sounds vague, and protocols vary. Short answer: most clinical \u201cpower\u201d is best expressed as energy flux density (EFD) 1 for focused ESWT, and pressure (bar) 2 for radial\/pressure-wave devices. Typical therapeutic EFD sits [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kmslaser.com\/fr\/machine-de-therapie-par-ondes-de-choc-puissance-quelle-est-la-puissance-typique-quelle-est-la-puissance-sure-et-comment-comparer-les-marques\/\" \/>\n<meta property=\"og:site_name\" content=\"KMSLaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-05T12:23:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/1-a-professional-medical-equipment-trade-show-booth-.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"679\" \/>\n\t<meta property=\"og:image:height\" content=\"453\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sophia Wu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sophia Wu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Puissance des machines de th\u00e9rapie par ondes de choc : qu'est-ce qui est typique, qu'est-ce qui est s\u00fbr, et comment comparer les marques ? - KMSLaser","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kmslaser.com\/fr\/machine-de-therapie-par-ondes-de-choc-puissance-quelle-est-la-puissance-typique-quelle-est-la-puissance-sure-et-comment-comparer-les-marques\/","og_locale":"fr_FR","og_type":"article","og_title":"Shockwave Therapy Machine Power: what\u2019s typical, what\u2019s safe, and how do you compare brands?","og_description":"I often hear, \u201cWhat\u2019s the real power on this shockwave unit?\u201d I get why that worries you. Specs look confusing, sales talk sounds vague, and protocols vary. Short answer: most clinical \u201cpower\u201d is best expressed as energy flux density (EFD) 1 for focused ESWT, and pressure (bar) 2 for radial\/pressure-wave devices. Typical therapeutic EFD sits [&hellip;]","og_url":"https:\/\/kmslaser.com\/fr\/machine-de-therapie-par-ondes-de-choc-puissance-quelle-est-la-puissance-typique-quelle-est-la-puissance-sure-et-comment-comparer-les-marques\/","og_site_name":"KMSLaser","article_published_time":"2025-10-05T12:23:30+00:00","og_image":[{"width":679,"height":453,"url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/1-a-professional-medical-equipment-trade-show-booth-.jpg","type":"image\/jpeg"}],"author":"Sophia Wu","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Sophia Wu","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#article","isPartOf":{"@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/"},"author":{"name":"Sophia Wu","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588"},"headline":"Shockwave Therapy Machine Power: what\u2019s typical, what\u2019s safe, and how do you compare brands?","datePublished":"2025-10-05T12:23:30+00:00","mainEntityOfPage":{"@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/"},"wordCount":814,"commentCount":0,"publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"image":{"@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/1-a-professional-medical-equipment-trade-show-booth-.jpg","articleSection":["Shockwave Therapy Machine"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/","url":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/","name":"Puissance des machines de th\u00e9rapie par ondes de choc : qu'est-ce qui est typique, qu'est-ce qui est s\u00fbr, et comment comparer les marques ? - KMSLaser","isPartOf":{"@id":"https:\/\/kmslaser.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#primaryimage"},"image":{"@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/1-a-professional-medical-equipment-trade-show-booth-.jpg","datePublished":"2025-10-05T12:23:30+00:00","breadcrumb":{"@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#primaryimage","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/1-a-professional-medical-equipment-trade-show-booth-.jpg","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/09\/1-a-professional-medical-equipment-trade-show-booth-.jpg","width":679,"height":453},{"@type":"BreadcrumbList","@id":"https:\/\/kmslaser.com\/shockwave-therapy-machine-power-whats-typical-whats-safe-and-how-do-you-compare-brands\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/kmslaser.com\/"},{"@type":"ListItem","position":2,"name":"Shockwave Therapy Machine Power: what\u2019s typical, what\u2019s safe, and how do you compare brands?"}]},{"@type":"WebSite","@id":"https:\/\/kmslaser.com\/#website","url":"https:\/\/kmslaser.com\/","name":"KMSLaser","description":"","publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kmslaser.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/kmslaser.com\/#organization","name":"KMSLaser","url":"https:\/\/kmslaser.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","width":180,"height":71,"caption":"KMSLaser"},"image":{"@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588","name":"Sophia Wu","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","caption":"Sophia Wu"},"url":"https:\/\/kmslaser.com\/fr\/author\/sophia\/"}]}},"_links":{"self":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/posts\/8070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/comments?post=8070"}],"version-history":[{"count":0,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/posts\/8070\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/media\/8071"}],"wp:attachment":[{"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/media?parent=8070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/categories?post=8070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kmslaser.com\/fr\/wp-json\/wp\/v2\/tags?post=8070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}