{"id":9009,"date":"2026-01-19T23:53:03","date_gmt":"2026-01-19T23:53:03","guid":{"rendered":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/"},"modified":"2026-01-19T23:53:03","modified_gmt":"2026-01-19T23:53:03","slug":"que-piezas-consumibles-comunes-debo-tener-en-stock-al-comprar-una-maquina-de-terapia-de-ondas-de-choque","status":"publish","type":"post","link":"https:\/\/kmslaser.com\/es\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/","title":{"rendered":"\u00bfQu\u00e9 piezas consumibles comunes debo tener en stock al comprar una m\u00e1quina de terapia de ondas de choque?"},"content":{"rendered":"<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866609683-1.jpg\" alt=\"Primer plano de piezas de dispositivos m\u00e9dicos en bandeja (ID#1)\" class=\"top-image-square\">\n<\/p>\n<p>Nada nos frustra m\u00e1s <a href=\"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfPCD\/classification.cfm?ID=NQP\" target=\"_blank\" rel=\"noopener\">Clasificaci\u00f3n de la FDA de los dispositivos de ondas de choque<\/a> <sup id=\"ref-1\"><a href=\"#footnote-1\" class=\"footnote-ref\">1<\/a><\/sup> durante nuestras llamadas de soporte postventa que escuchar que una cl\u00ednica ha detenido los tratamientos debido a un solo sello desgastado. Vemos que este tiempo de inactividad le cuesta a las empresas miles en ingresos perdidos.<\/p>\n<p><strong>Para garantizar un funcionamiento ininterrumpido, debe abastecerse de puntas transmisoras, kits de revisi\u00f3n de piezas de mano (que contienen proyectiles y tubos gu\u00eda), tapas protectoras de silicona y juegos de juntas t\u00f3ricas de repuesto. Estos componentes experimentan el mayor estr\u00e9s f\u00edsico y requieren un reemplazo regular cada 1 a 2 millones de pulsos.<\/strong><\/p>\n<p>Analicemos la lista de inventario espec\u00edfica que necesita para mantener una operaci\u00f3n de servicio confiable <a href=\"https:\/\/www.hse.gov.uk\/vibration\/hav\/index.htm\" target=\"_blank\" rel=\"noopener\">gu\u00eda de vibraci\u00f3n mano-brazo<\/a> <sup id=\"ref-2\"><a href=\"#footnote-2\" class=\"footnote-ref\">2<\/a><\/sup>.<\/p>\n<h2>\u00bfQu\u00e9 componentes espec\u00edficos dentro de la pieza de mano de ondas de choque se desgastan m\u00e1s r\u00e1pido?<\/h2>\n<p>Cuando ensamblamos estas piezas de mano en nuestra l\u00ednea de producci\u00f3n, prestamos especial atenci\u00f3n a las partes m\u00f3viles que manejan la aceleraci\u00f3n neum\u00e1tica. La fricci\u00f3n interna generada durante los tratamientos de alta frecuencia inevitablemente degrada ciertos materiales con el tiempo.<\/p>\n<p><strong>El proyectil (a menudo llamado bala) y el tubo gu\u00eda dentro del ca\u00f1\u00f3n son los que m\u00e1s se desgastan. Estas dos partes soportan un impacto y fricci\u00f3n constantes a alta velocidad, lo que lleva a la deformaci\u00f3n o ensanchamiento del tubo, lo que causa directamente una p\u00e9rdida de salida de energ\u00eda.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866611111-2.jpg\" alt=\"Pieza de mano de terapia de ondas de choque con etiquetas (ID#2)\" title=\"Pieza de mano de terapia\"><\/p>\n<p>Comprender la mec\u00e1nica interna de una pieza de mano de ondas de choque radial le ayuda a darse cuenta de por qu\u00e9 ciertas partes son consumibles. El sistema funciona seg\u00fan un principio bal\u00edstico <a href=\"https:\/\/en.wikipedia.org\/wiki\/Ballistics\" target=\"_blank\" rel=\"noopener\">principio de funcionamiento bal\u00edstico<\/a> <sup id=\"ref-3\"><a href=\"#footnote-3\" class=\"footnote-ref\">3<\/a><\/sup>. El aire comprimido acelera un proyectil <a href=\"https:\/\/www.storzmedical.com\/en\/disciplines\/orthopaedics\/product-overview\/masterpuls-one\" target=\"_blank\" rel=\"noopener\">especificaciones de la onda de presi\u00f3n radial<\/a> <sup id=\"ref-4\"><a href=\"#footnote-4\" class=\"footnote-ref\">4<\/a><\/sup> dentro de un tubo gu\u00eda. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3438862\/\" target=\"_blank\" rel=\"noopener\">el sistema funciona seg\u00fan un principio bal\u00edstico<\/a> <sup id=\"ref-5\"><a href=\"#footnote-5\" class=\"footnote-ref\">5<\/a><\/sup> Este proyectil luego golpea la cabeza del transmisor, creando la onda ac\u00fastica.<\/p>\n<h3>El Proyectil (Bala)<\/h3>\n<p>El proyectil es el caballo de batalla del sistema. En nuestro laboratorio de pruebas, observamos que el proyectil golpea la cabeza del transmisor miles de veces por minuto. Con el tiempo, el metal se fatiga. La forma del proyectil puede cambiar ligeramente, o el recubrimiento magn\u00e9tico (si se usa para mecanismos de retorno) puede desgastarse. Si un proyectil se deforma, no viajar\u00e1 suavemente. Esto puede da\u00f1ar el tubo gu\u00eda y resultar en ondas de choque inconsistentes.<\/p>\n<h3>El Tubo Gu\u00eda (Ca\u00f1\u00f3n)<\/h3>\n<p>El tubo es donde viaja el proyectil. Incluso con lubricantes de alta calidad, se produce fricci\u00f3n. Con millones de ciclos, el di\u00e1metro interior del tubo se ensancha ligeramente. Cuando el espacio entre el proyectil y la pared del tubo aumenta, el aire comprimido escapa alrededor de la bala en lugar de empujarla. Esta es una causa principal de p\u00e9rdida de potencia. Puede configurar la m\u00e1quina a 4 Bar, pero la salida se siente como 2 Bar.<\/p>\n<h3>Juntas t\u00f3ricas y sellos<\/h3>\n<p>Mientras que las partes met\u00e1licas soportan el impacto, los sellos de goma mantienen la presi\u00f3n. Cada vez que se abre la pieza de mano para limpieza o mantenimiento, estos sellos se alteran. Tambi\u00e9n se secan con el tiempo. Si una junta t\u00f3rica falla <a href=\"https:\/\/en.wikipedia.org\/wiki\/O-ring\" target=\"_blank\" rel=\"noopener\">Mec\u00e1nica del sello de junta t\u00f3rica<\/a> <sup id=\"ref-6\"><a href=\"#footnote-6\" class=\"footnote-ref\">6<\/a><\/sup>, el sistema neum\u00e1tico pierde presi\u00f3n. Esto obliga al compresor a trabajar m\u00e1s, lo que puede acortar la vida \u00fatil de la unidad principal.<\/p>\n<h3>Vida \u00fatil de los componentes e indicadores de falla<\/h3>\n<p>Hemos compilado una tabla basada en nuestros datos de servicio para ayudarlo a identificar cu\u00e1ndo fallan estas partes espec\u00edficas.<\/p>\n<table>\n<thead>\n<tr>\n<th align=\"left\">Nombre del componente<\/th>\n<th align=\"left\">Funci\u00f3n principal<\/th>\n<th align=\"left\">Se\u00f1al de desgaste t\u00edpica<\/th>\n<th align=\"left\">Consecuencia de ignorar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\"><strong>Proyectil (Bala)<\/strong><\/td>\n<td align=\"left\">Transfiere energ\u00eda cin\u00e9tica<\/td>\n<td align=\"left\">Punta aplanada o manchas de \u00f3xido<\/td>\n<td align=\"left\">Da\u00f1o en la cabeza del transmisor<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Tubo Gu\u00eda<\/strong><\/td>\n<td align=\"left\">Dirige la trayectoria del proyectil<\/td>\n<td align=\"left\">Rayaduras internas o calibre ensanchado<\/td>\n<td align=\"left\">P\u00e9rdida de potencia significativa<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Sellos t\u00f3ricos<\/strong><\/td>\n<td align=\"left\">Mantiene la presi\u00f3n del aire<\/td>\n<td align=\"left\">Grietas, sequedad o aflojamiento<\/td>\n<td align=\"left\">Fugas de aire y tensi\u00f3n en el compresor<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Resorte amortiguador<\/strong><\/td>\n<td align=\"left\">Absorbe el impacto del retroceso<\/td>\n<td align=\"left\">P\u00e9rdida de tensi\u00f3n<\/td>\n<td align=\"left\">Increased vibration in therapist&#39;s hand<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u00bfCu\u00e1ntos disparos puedo esperar de un juego est\u00e1ndar de bala y ca\u00f1\u00f3n?<\/h2>\n<p>Nuestros ingenieros prueban rigurosamente lotes de muestras, ejecut\u00e1ndolos continuamente para determinar los puntos de falla. Si bien los materiales de marketing a menudo prometen cifras m\u00e1s altas, el uso en el mundo real en cl\u00ednicas concurridas proporciona una estimaci\u00f3n m\u00e1s conservadora y precisa.<\/p>\n<p><strong>Generalmente, puede esperar entre 1 mill\u00f3n y 2 millones de disparos de un juego est\u00e1ndar de bala y barril antes de que el rendimiento disminuya. Sin embargo, operar consistentemente en configuraciones de presi\u00f3n m\u00e1xima o descuidar la limpieza diaria puede reducir esta vida \u00fatil a menos de 1 mill\u00f3n de disparos.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866611669-3.jpg\" alt=\"T\u00e9cnico manipulando componentes de dispositivos m\u00e9dicos (ID#3)\" title=\"Componentes del dispositivo\"><\/p>\n<p>El concepto de \"1 mill\u00f3n de disparos\" puede ser abstracto. Es vital traducirlo a t\u00e9rminos comerciales para comprender su calendario de reordenaci\u00f3n.<\/p>\n<h3>C\u00e1lculo del Ciclo de Reemplazo<\/h3>\n<p>Si un protocolo de tratamiento est\u00e1ndar para la celulitis o el dolor de espalda implica de 2.000 a 3.000 disparos por sesi\u00f3n, y una cl\u00ednica trata a 5 pacientes al d\u00eda, eso son aproximadamente 15.000 disparos al d\u00eda.<\/p>\n<ul>\n<li><strong>Uso semanal:<\/strong> 75,000 &#8211; 100,000 shots.<\/li>\n<li><strong>Uso mensual:<\/strong> 300,000 &#8211; 400,000 shots.<\/li>\n<\/ul>\n<p>A este ritmo, un solo kit de revisi\u00f3n (bala y tubo) durar\u00e1 aproximadamente de 3 a 4 meses. Si est\u00e1 distribuyendo a cl\u00ednicas de alto volumen, necesitar\u00e1n al menos 3 kits por a\u00f1o por m\u00e1quina.<\/p>\n<h3>Factores que Acortan la Vida \u00datil<\/h3>\n<p>No todos los disparos son iguales. La longevidad de las piezas consumibles depende en gran medida de c\u00f3mo se utiliza la m\u00e1quina:<\/p>\n<ul>\n<li><strong>Configuraciones de Presi\u00f3n:<\/strong> Hacer funcionar la m\u00e1quina a 4 Bar o 5 Bar crea fuerzas de impacto mucho mayores que hacerla funcionar a 1.5 Bar. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC5434407\/\" target=\"_blank\" rel=\"noopener\">crea fuerzas de impacto mucho mayores<\/a> <sup id=\"ref-7\"><a href=\"#footnote-7\" class=\"footnote-ref\">7<\/a><\/sup> Los tratamientos de alta presi\u00f3n desgastan la bala m\u00e1s r\u00e1pido.<\/li>\n<li><strong>Frecuencia (Hz):<\/strong> Una mayor frecuencia genera m\u00e1s calor. El calor expande el metal y degrada las juntas t\u00f3ricas de goma.<\/li>\n<li><strong>Lubricaci\u00f3n:<\/strong> Si el usuario no limpia y lubrica el ca\u00f1\u00f3n (si el modelo espec\u00edfico lo requiere), la fricci\u00f3n aumenta dr\u00e1sticamente.<\/li>\n<\/ul>\n<h3>La econom\u00eda de los kits de revisi\u00f3n<\/h3>\n<p>Los distribuidores a menudo se preocupan por el costo de los kits de revisi\u00f3n. Sin embargo, cuando se desglosa el ROI, el costo es insignificante en comparaci\u00f3n con los ingresos generados. Un kit de revisi\u00f3n asegura que la m\u00e1quina contin\u00fae generando dinero.<\/p>\n<h3>An\u00e1lisis de costos para distribuidores<\/h3>\n<table>\n<thead>\n<tr>\n<th align=\"left\">Art\u00edculo<\/th>\n<th align=\"left\">Costo estimado (B2B)<\/th>\n<th align=\"left\">Amortiguadores proporcionados<\/th>\n<th align=\"left\">Potencial de ingresos (nivel de cl\u00ednica)<\/th>\n<th align=\"left\">Estado del ROI<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\"><strong>Kit de revisi\u00f3n<\/strong><\/td>\n<td align=\"left\">$50 &#8211; $150<\/td>\n<td align=\"left\">2,000,000<\/td>\n<td align=\"left\">$100,000+ (aprox. $50\/tratamiento)<\/td>\n<td align=\"left\"><strong>Extremadamente alto<\/strong><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Bala gen\u00e9rica<\/strong><\/td>\n<td align=\"left\">$20 &#8211; $40<\/td>\n<td align=\"left\">500,000 (No confiable)<\/td>\n<td align=\"left\">Riesgo de da\u00f1o de la m\u00e1quina<\/td>\n<td align=\"left\"><strong>Negativo<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Nota: El potencial de ingresos asume un precio promedio de tratamiento. La conclusi\u00f3n clave es que el costo del consumible es una fracci\u00f3n min\u00fascula de los ingresos, lo que justifica un stock robusto.<\/em><\/p>\n<h2>\u00bfNecesito tener en inventario varios tama\u00f1os de cabezales transmisores?<\/h2>\n<p>A menudo notamos \u00f3rdenes de compra que se adhieren estrictamente al cabezal est\u00e1ndar de 15 mm, omitiendo otras opciones cruciales. Al limitar su inventario a un tama\u00f1o, restringe la versatilidad de la m\u00e1quina y los tratamientos que sus clientes pueden ofrecer.<\/p>\n<p><strong>S\u00ed, absolutamente necesita tener en stock varios tama\u00f1os de cabezales transmisores, espec\u00edficamente las opciones de 15 mm, 20 mm y 35 mm. Los diferentes di\u00e1metros regulan la profundidad y la dispersi\u00f3n de la energ\u00eda, haciendo que los cabezales espec\u00edficos sean necesarios para tratar \u00e1reas delicadas frente a grupos musculares grandes.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866612277-4.jpg\" alt=\"Diagrama del sistema de terapia de ondas de choque radial (ID#4)\" title=\"Sistema de ondas de choque\"><\/p>\n<p>La terapia de ondas de choque no es una <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/30053303\/\" target=\"_blank\" rel=\"noopener\">transmisi\u00f3n de energ\u00eda de ondas de choque radiales<\/a> <sup id=\"ref-8\"><a href=\"#footnote-8\" class=\"footnote-ref\">8<\/a><\/sup> \"aplicaci\u00f3n \"talla \u00fanica\". El cabezal transmisor (la parte que toca la piel) determina la f\u00edsica de la onda que entra en el cuerpo.<\/p>\n<h3>Comprensi\u00f3n de la dispersi\u00f3n de energ\u00eda<\/h3>\n<p>Las ondas de choque radiales divergen. Un cabezal m\u00e1s peque\u00f1o crea una energ\u00eda m\u00e1s enfocada e intensa en la superficie. Un cabezal m\u00e1s grande dispersa la energ\u00eda sobre un \u00e1rea m\u00e1s amplia.<\/p>\n<ul>\n<li><strong>Small Heads (6mm &#8211; 10mm):<\/strong> Estos se utilizan para puntos de acupuntura o puntos gatillo muy espec\u00edficos. Son intensos y pueden ser dolorosos si se usan en \u00e1reas amplias.<\/li>\n<li><strong>Cabezales est\u00e1ndar (15 mm):<\/strong> Este es el cabezal de prop\u00f3sito general. Funciona bien para tendones, como en el codo de tenista o la tendinitis de Aquiles.<\/li>\n<li><strong>Large Heads (20mm &#8211; 35mm):<\/strong> Estos son cr\u00edticos <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/26439320\/\" target=\"_blank\" rel=\"noopener\">cr\u00edticos para la est\u00e9tica (celulitis)<\/a> <sup id=\"ref-9\"><a href=\"#footnote-9\" class=\"footnote-ref\">9<\/a><\/sup> para est\u00e9tica (celulitis) y grupos musculares grandes (cu\u00e1driceps, espalda). Proporcionan un efecto de masaje m\u00e1s suave y cubren terreno r\u00e1pidamente.<\/li>\n<\/ul>\n<h3>Tratamientos Especializados Impulsan las Ventas<\/h3>\n<p>If you are selling to beauty salons, the standard 15mm head is insufficient. They need large 35mm transmitters for body contouring. If you sell to men&#39;s health clinics, they require specialized, softer heads for ED treatments. Stocking these variations allows you to upsell &quot;Specialist Kits&quot; alongside the main unit.<\/p>\n<h3>Diferencias de Material<\/h3>\n<p>Los transmisores no se tratan solo del tama\u00f1o, sino del material.<\/p>\n<ul>\n<li><strong>Acero Inoxidable:<\/strong> El est\u00e1ndar para impacto profundo y afecciones ortop\u00e9dicas.<\/li>\n<li><strong>Cer\u00e1mica o Aleaciones de Titanio:<\/strong> A menudo se utilizan para la transmisi\u00f3n de alta energ\u00eda.<\/li>\n<li><strong>Punta Suave\/Silicona:<\/strong> Esencial para tratar \u00e1reas sensibles o fascia superficial donde el contacto met\u00e1lico es demasiado doloroso.<\/li>\n<\/ul>\n<h3>Proporciones de Stock Recomendadas<\/h3>\n<p>Bas\u00e1ndonos en los patrones de uso t\u00edpicos, recomendamos la siguiente mezcla de inventario para su departamento de repuestos.<\/p>\n<table>\n<thead>\n<tr>\n<th align=\"left\">Tama\u00f1o del Transmisor<\/th>\n<th align=\"left\">Aplicaci\u00f3n Principal<\/th>\n<th align=\"left\">Prioridad de Stock<\/th>\n<th align=\"left\">Usuario T\u00edpico<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\"><strong>15mm Radial<\/strong><\/td>\n<td align=\"left\">Tendinitis, Espolones calc\u00e1neos<\/td>\n<td align=\"left\">Alto (Incluir en cada caja)<\/td>\n<td align=\"left\">Fisioterapia, Quiropr\u00e1ctico<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>20mm Radial<\/strong><\/td>\n<td align=\"left\">Dolor miofascial, Espalda<\/td>\n<td align=\"left\">Alto<\/td>\n<td align=\"left\">Fisioterapia, Masaje<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>35mm Grande<\/strong><\/td>\n<td align=\"left\">Celulitis, Linf\u00e1tico<\/td>\n<td align=\"left\">Medio<\/td>\n<td align=\"left\">Sal\u00f3n de belleza<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>6mm\/Enfoque<\/strong><\/td>\n<td align=\"left\">Puntos gatillo<\/td>\n<td align=\"left\">Bajo (Pedido especial)<\/td>\n<td align=\"left\">Fisioterapeuta especialista<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Punta blanda\/ED<\/strong><\/td>\n<td align=\"left\">Men&#39;s Health<\/td>\n<td align=\"left\">Nicho (Alto valor)<\/td>\n<td align=\"left\">Urolog\u00eda\/Bienestar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u00bfC\u00f3mo puedo saber si una pieza desgastada est\u00e1 reduciendo la efectividad del tratamiento?<\/h2>\n<p>En nuestros controles de calidad finales <a href=\"https:\/\/www.iso.org\/standard\/59752.html\" target=\"_blank\" rel=\"noopener\">la gesti\u00f3n de calidad ISO 13485<\/a> <sup id=\"ref-10\"><a href=\"#footnote-10\" class=\"footnote-ref\">10<\/a><\/sup> checks, we use precision meters to verify output, but your customers won&#8217;t have that equipment. We must teach them to recognize the subtle physical and auditory cues that indicate a machine is losing its therapeutic power.<\/p>\n<p><strong>You can identify worn-out parts by listening for a dull &#8220;thud&#8221; instead of a crisp &#8220;snap,&#8221; checking for excessive handle heating, and observing if the projectile fails to slide freely during the &#8220;tube test.&#8221;<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866612831-5.jpg\" alt=\"Profesional m\u00e9dico utilizando m\u00e1quina de terapia de ondas de choque (ID#5)\" title=\"M\u00e1quina de terapia\"><\/p>\n<p>Una m\u00e1quina que todav\u00eda hace ruido no est\u00e1 necesariamente funcionando correctamente. Cuando las piezas se desgastan, la energ\u00eda es absorbida por la fricci\u00f3n y el calor en lugar de transferirse al paciente. Esto hace que el tratamiento sea ineficaz.<\/p>\n<h3>La Prueba Auditiva<\/h3>\n<p>Una pieza de mano de onda de choque saludable tiene un ritmo distintivo. El sonido debe ser un \"clac\" o \"chasquido\" met\u00e1lico y agudo. Esto indica que el proyectil est\u00e1 golpeando el transmisor con toda su fuerza y rebotando limpiamente.<\/p>\n<ul>\n<li><strong>El Sonido de Advertencia:<\/strong> Si el sonido se convierte en un golpeteo sordo y apagado, o si el ritmo se vuelve irregular (salt\u00e1ndose compases), el proyectil o el tubo est\u00e1n desgastados. La bala se arrastra dentro del ca\u00f1\u00f3n.<\/li>\n<\/ul>\n<h3>La Comprobaci\u00f3n de Calor<\/h3>\n<p>La energ\u00eda no se puede destruir, solo transferir. En una m\u00e1quina que funciona, la energ\u00eda se convierte en una onda mec\u00e1nica. En una m\u00e1quina desgastada, esa energ\u00eda cin\u00e9tica se convierte en calor debido a la fricci\u00f3n.<\/p>\n<ul>\n<li><strong>S\u00edntoma:<\/strong> Si la pieza de mano se calienta inc\u00f3modamente al tacto despu\u00e9s de solo unos minutos de uso, es una se\u00f1al de fricci\u00f3n interna. Esto generalmente significa que las juntas t\u00f3ricas han fallado o que el tubo est\u00e1 da\u00f1ado.<\/li>\n<\/ul>\n<h3>La \"Prueba del Tubo\" (Prueba de Gravedad)<\/h3>\n<p>Esta es una prueba sencilla que ense\u00f1amos a todos nuestros distribuidores.<\/p>\n<ol>\n<li>Retire la cabeza del transmisor y el tap\u00f3n de rosca.<\/li>\n<li>Saque el proyectil (bala).<\/li>\n<li>Limpie la bala y el tubo.<\/li>\n<li>Deje caer la bala de nuevo en el tubo.<\/li>\n<li>Incline la pieza de mano hacia arriba y hacia abajo.<br \/><strong>Resultado:<\/strong> La bala debe deslizarse hacia arriba y hacia abajo libremente solo con la gravedad. Si se atasca o se mueve lentamente, el tubo est\u00e1 deformado o la bala est\u00e1 hinchada. Es hora de reemplazar el kit.<\/li>\n<\/ol>\n<h3>Inspecci\u00f3n visual de los transmisores<\/h3>\n<p>La cabeza del transmisor recibe golpes. Con el tiempo, la superficie de impacto (donde golpea la bala) puede picarse o volverse c\u00f3ncava.<\/p>\n<ul>\n<li><strong>Erosi\u00f3n:<\/strong> Si la parte posterior del transmisor est\u00e1 picada, la superficie de contacto se reduce. Esto dispersa la energ\u00eda.<\/li>\n<li><strong>Desgaste externo:<\/strong> En el lado del paciente, el metal debe estar liso. Los ara\u00f1azos pueden albergar bacterias y sentirse \u00e1speros en la piel.<\/li>\n<\/ul>\n<h3>Mensajes de error<\/h3>\n<p>Las m\u00e1quinas modernas, incluidas las que fabricamos, tienen sensores.<\/p>\n<ul>\n<li><strong>\"Advertencia de \"Sobrecalentamiento\":<\/strong> El sobrecalentamiento frecuente a menudo apunta a un fallo de los consumibles, no a un fallo de la unidad principal.<\/li>\n<li><strong>\"Error de presi\u00f3n\":<\/strong> Si la m\u00e1quina no puede alcanzar la presi\u00f3n de Bar establecida, es probable que est\u00e9 perdiendo aire a trav\u00e9s de sellos desgastados.<\/li>\n<\/ul>\n<h2>Conclusi\u00f3n<\/h2>\n<p>The reliability of a shockwave therapy machine depends entirely on the condition of its consumables. By proactively stocking transmitter tips, revision kits (bullets and tubes), and O-rings, you prevent costly downtime for your clients. We recommend keeping at least two full revision kits and a variety of transmitter heads in stock for every machine you sell. This strategy not only protects your brand&#39;s reputation for quality but also creates a steady stream of recurring revenue from spare parts sales.<\/p>\n<h2>Notas al pie<\/h2>\n<p><span id=\"footnote-1\"><br \/>\n1. Proporciona contexto regulatorio oficial para el tipo de dispositivo. <a href=\"#ref-1\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-2\"><br \/>\n2. Enlaces a normas oficiales de seguridad relativas a la vibraci\u00f3n mano-brazo. <a href=\"#ref-2\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-3\"><br \/>\n3. Explica el principio f\u00edsico del movimiento de proyectiles. <a href=\"#ref-3\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-4\"><br \/>\n4. Ejemplo de documentaci\u00f3n t\u00e9cnica l\u00edder en la industria para sistemas radiales. <a href=\"#ref-4\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-5\"><br \/>\n5. Valida el mecanismo bal\u00edstico neum\u00e1tico de la generaci\u00f3n de ondas de choque radiales. <a href=\"#ref-5\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-6\"><br \/>\n6. Informaci\u00f3n de fondo sobre la funci\u00f3n mec\u00e1nica de las juntas t\u00f3ricas. <a href=\"#ref-6\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-7\"><br \/>\n7. Corrobora la relaci\u00f3n entre los ajustes de presi\u00f3n de la barra y la salida de energ\u00eda. <a href=\"#ref-7\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-8\"><br \/>\n8. Investigaci\u00f3n cient\u00edfica que respalda la f\u00edsica de la dispersi\u00f3n de energ\u00eda. <a href=\"#ref-8\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-9\"><br \/>\n9. Cita evidencia cl\u00ednica que respalda la terapia de ondas de choque para el tratamiento de la celulitis. <a href=\"#ref-9\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-10\"><br \/>\n10. Referencia de est\u00e1ndares de calidad internacionales en fabricaci\u00f3n m\u00e9dica. <a href=\"#ref-10\" class=\"footnote-backref\" title=\"\u8fd4\u56de\u6587\u7ae0\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Nothing frustrates us more FDA classification of shockwave devices 1 during our post-sales support calls than hearing a clinic has stopped treatments because of a single worn-out seal. We see this downtime cost businesses thousands in lost revenue. To ensure uninterrupted operation, you must stock up on transmitter tips, handpiece revision kits (containing projectiles and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":9004,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[60],"tags":[],"class_list":["post-9009","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-shockwave-therapy-machine"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine? - KMSLaser<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kmslaser.com\/es\/que-piezas-consumibles-comunes-debo-tener-en-stock-al-comprar-una-maquina-de-terapia-de-ondas-de-choque\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine?\" \/>\n<meta property=\"og:description\" content=\"Nothing frustrates us more FDA classification of shockwave devices 1 during our post-sales support calls than hearing a clinic has stopped treatments because of a single worn-out seal. We see this downtime cost businesses thousands in lost revenue. To ensure uninterrupted operation, you must stock up on transmitter tips, handpiece revision kits (containing projectiles and [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kmslaser.com\/es\/que-piezas-consumibles-comunes-debo-tener-en-stock-al-comprar-una-maquina-de-terapia-de-ondas-de-choque\/\" \/>\n<meta property=\"og:site_name\" content=\"KMSLaser\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-19T23:53:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866609683-1.jpg\" \/>\n<meta name=\"author\" content=\"Sophia Wu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sophia Wu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/\"},\"author\":{\"name\":\"Sophia Wu\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\"},\"headline\":\"What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine?\",\"datePublished\":\"2026-01-19T23:53:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/\"},\"wordCount\":1963,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1768866609683-1.jpg\",\"articleSection\":[\"Shockwave Therapy Machine\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/\",\"name\":\"What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine? - KMSLaser\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1768866609683-1.jpg\",\"datePublished\":\"2026-01-19T23:53:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#primaryimage\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1768866609683-1.jpg\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1768866609683-1.jpg\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/kmslaser.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"name\":\"KMSLaser\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/kmslaser.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\",\"name\":\"KMSLaser\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"width\":180,\"height\":71,\"caption\":\"KMSLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\",\"name\":\"Sophia Wu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"caption\":\"Sophia Wu\"},\"url\":\"https:\\\/\\\/kmslaser.com\\\/es\\\/author\\\/sophia\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u00bfQu\u00e9 piezas consumibles comunes debo tener en stock al comprar una m\u00e1quina de terapia de ondas de choque? - KMSLaser","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kmslaser.com\/es\/que-piezas-consumibles-comunes-debo-tener-en-stock-al-comprar-una-maquina-de-terapia-de-ondas-de-choque\/","og_locale":"es_MX","og_type":"article","og_title":"What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine?","og_description":"Nothing frustrates us more FDA classification of shockwave devices 1 during our post-sales support calls than hearing a clinic has stopped treatments because of a single worn-out seal. We see this downtime cost businesses thousands in lost revenue. To ensure uninterrupted operation, you must stock up on transmitter tips, handpiece revision kits (containing projectiles and [&hellip;]","og_url":"https:\/\/kmslaser.com\/es\/que-piezas-consumibles-comunes-debo-tener-en-stock-al-comprar-una-maquina-de-terapia-de-ondas-de-choque\/","og_site_name":"KMSLaser","article_published_time":"2026-01-19T23:53:03+00:00","og_image":[{"url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866609683-1.jpg","type":"","width":"","height":""}],"author":"Sophia Wu","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Sophia Wu","Tiempo de lectura":"10 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#article","isPartOf":{"@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/"},"author":{"name":"Sophia Wu","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588"},"headline":"What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine?","datePublished":"2026-01-19T23:53:03+00:00","mainEntityOfPage":{"@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/"},"wordCount":1963,"commentCount":0,"publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"image":{"@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866609683-1.jpg","articleSection":["Shockwave Therapy Machine"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/","url":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/","name":"\u00bfQu\u00e9 piezas consumibles comunes debo tener en stock al comprar una m\u00e1quina de terapia de ondas de choque? - KMSLaser","isPartOf":{"@id":"https:\/\/kmslaser.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#primaryimage"},"image":{"@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866609683-1.jpg","datePublished":"2026-01-19T23:53:03+00:00","breadcrumb":{"@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#primaryimage","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866609683-1.jpg","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/01\/v2-article-1768866609683-1.jpg","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/kmslaser.com\/what-common-consumable-parts-should-i-stock-up-on-when-purchasing-a-shockwave-therapy-machine\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/kmslaser.com\/"},{"@type":"ListItem","position":2,"name":"What common consumable parts should I stock up on when purchasing a Shockwave Therapy Machine?"}]},{"@type":"WebSite","@id":"https:\/\/kmslaser.com\/#website","url":"https:\/\/kmslaser.com\/","name":"KMSLaser","description":"","publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kmslaser.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/kmslaser.com\/#organization","name":"KMSLaser","url":"https:\/\/kmslaser.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","width":180,"height":71,"caption":"KMSLaser"},"image":{"@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588","name":"Sophia Wu","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","caption":"Sophia Wu"},"url":"https:\/\/kmslaser.com\/es\/author\/sophia\/"}]}},"_links":{"self":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/posts\/9009","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/comments?post=9009"}],"version-history":[{"count":0,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/posts\/9009\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/media\/9004"}],"wp:attachment":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/media?parent=9009"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/categories?post=9009"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/tags?post=9009"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}