{"id":8793,"date":"2025-12-23T14:22:14","date_gmt":"2025-12-23T14:22:14","guid":{"rendered":"https:\/\/kmslaser.com\/?p=8793"},"modified":"2026-01-10T14:25:50","modified_gmt":"2026-01-10T14:25:50","slug":"cuales-son-las-averias-comunes-de-las-maquinas-de-terapia-de-ondas-de-choque-y-sus-soluciones-correspondientes","status":"publish","type":"post","link":"https:\/\/kmslaser.com\/es\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/","title":{"rendered":"\u00bfCu\u00e1les son las aver\u00edas comunes de las m\u00e1quinas de terapia de ondas de choque y sus soluciones correspondientes?"},"content":{"rendered":"<p><iframe data-testid=\"embed-iframe\" style=\"border-radius:12px\" src=\"https:\/\/open.spotify.com\/embed\/episode\/3JcvoGMUxIovivE0nO2jnJ?utm_source=generator&amp;theme=0\" width=\"100%\" height=\"152\" frameborder=\"0\" allowfullscreen=\"\" allow=\"autoplay; clipboard-write; encrypted-media; fullscreen; picture-in-picture\" loading=\"lazy\"><\/iframe><\/p>\n<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/1-1-machine-photorealistic-modern-high-end-shockwave-therapy-clean-well-li-e3355d5b.jpg\" alt=\"M\u00e1quina moderna de alta gama de terapia de ondas de choque primer plano (ID#1)\" class=\"top-image-square\">\n<\/p>\n<p>En KMSLASER, entendemos que una m\u00e1quina rota significa citas canceladas y p\u00e9rdida de ingresos para su cl\u00ednica. El tiempo de inactividad es frustrante, pero conocer las se\u00f1ales de falla a tiempo puede salvar su negocio.<\/p>\n<p><strong>Las aver\u00edas comunes incluyen fallos en el sensor de presi\u00f3n, desgaste de la pieza de mano, problemas de la fuente de alimentaci\u00f3n y fallos de software. Las soluciones implican calibrar sensores, reemplazar balines o resortes desgastados, revisar conexiones de alimentaci\u00f3n y realizar actualizaciones regulares del firmware para garantizar una salida de energ\u00eda constante y la seguridad del paciente.<\/strong><\/p>\n<p>Let&#8217;s dive into the specific problems you might face and the practical steps to fix them, ensuring your equipment remains reliable and profitable.<\/p>\n<h2>\u00bfC\u00f3mo puedo identificar si mi m\u00e1quina de terapia de ondas de choque est\u00e1 experimentando una aver\u00eda com\u00fan?<\/h2>\n<p>Nuestro equipo de ingenier\u00eda a menudo ayuda a los clientes a detectar se\u00f1ales de advertencia tempranas antes de que ocurra una aver\u00eda total, ahorr\u00e1ndoles costosas reparaciones de emergencia. Ignorar cambios sutiles en el rendimiento puede llevar a problemas mayores m\u00e1s adelante.<\/p>\n<p><strong>Puede identificar aver\u00edas monitoreando una salida de energ\u00eda inconsistente, c\u00f3digos de error en la pantalla o ruidos inusuales del compresor. Adem\u00e1s, las quejas de los pacientes sobre la falta de sensaci\u00f3n o el dolor excesivo a menudo indican una deriva en la calibraci\u00f3n o un fallo del aplicador que requiere una inspecci\u00f3n inmediata.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg\" alt=\"Observaci\u00f3n diagn\u00f3stica profesional con m\u00e1quina (ID#2)\" title=\"Observaci\u00f3n diagn\u00f3stica\" \/><\/p>\n<p>Identificar una aver\u00eda no siempre significa esperar a que la m\u00e1quina deje de funcionar por completo. A menudo, el dispositivo le da pistas sutiles de que algo anda mal. Como propietario de un negocio o gerente de compras, capacitar a su personal para reconocer estas se\u00f1ales es la primera l\u00ednea de defensa.<\/p>\n<h3>Escuche el compresor y la pieza de mano<\/h3>\n<p>El sonido de su m\u00e1quina es un indicador clave de su estado de salud. Una m\u00e1quina de ondas de choque neum\u00e1tica saludable tiene un sonido r\u00edtmico y constante de golpeteo. Si escucha latidos irregulares, silbidos o un sonido de motor \"luchando\", a menudo apunta a una fuga de aire o a un compresor defectuoso.<\/p>\n<ul>\n<li><strong>Sonidos de silbido:<\/strong> Generalmente indican una fuga en la tuber\u00eda interna o en la conexi\u00f3n entre la unidad principal y la pieza de mano.<\/li>\n<li><strong>Traqueteo dentro de la pieza de mano:<\/strong> Esto a menudo significa que el proyectil (bal\u00edn) o el tubo est\u00e1n desgastados. Se pueden acumular fragmentos met\u00e1licos si los consumibles no se cambian a tiempo.<\/li>\n<\/ul>\n<h3>Monitorizar la consistencia de la salida de energ\u00eda<\/h3>\n<p>Uno de los signos m\u00e1s cr\u00edticos de mal funcionamiento es cuando la salida de energ\u00eda no coincide con el ajuste en la pantalla. A menudo escuchamos a los clientes decir que sus pacientes no sienten \"nada\" incluso con ajustes altos. Rara vez se trata de un problema de tolerancia del paciente; suele ser un problema de la m\u00e1quina.<\/p>\n<ul>\n<li><strong>Impacto d\u00e9bil:<\/strong> Si la presi\u00f3n se ajusta a un nivel alto (por ejemplo, 4 Bar) pero el impacto se siente d\u00e9bil, el compresor de aire puede estar perdiendo presi\u00f3n o el proyectil dentro de la pieza de mano est\u00e1 atascado.<\/li>\n<li><strong>Pulsos intermitentes:<\/strong> Si las ondas de choque se detienen y se inician de forma aleatoria, esto sugiere una conexi\u00f3n el\u00e9ctrica floja o una rotura de cable. Llamamos a esto la \"prueba de movimiento\": si mover el cable hace que la energ\u00eda se corte, el cable est\u00e1 da\u00f1ado.<\/li>\n<\/ul>\n<h3>Est\u00e9 atento a los c\u00f3digos de error y fallos en la pantalla<\/h3>\n<p>Modern beauty machines are equipped with sensors that detect internal faults. Never ignore an error code, even if a restart seems to fix it temporarily. These codes are the machine&#8217;s way of telling you that a specific component, like the pressure sensor or cooling fan, is operating outside its safe range.<\/p>\n<h3>Tabla: Indicadores sensoriales de posibles fallos<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Sentido<\/th>\n<th style=\"text-align: left;\">S\u00edntoma<\/th>\n<th style=\"text-align: left;\">Mal funcionamiento potencial<\/th>\n<th style=\"text-align: left;\">Acci\u00f3n inmediata<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>O\u00eddo<\/strong><\/td>\n<td style=\"text-align: left;\">Sonido de aire sibilante<\/td>\n<td style=\"text-align: left;\">Fuga en la manguera de aire o conector flojo<\/td>\n<td style=\"text-align: left;\">Compruebe todas las conexiones neum\u00e1ticas.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>O\u00eddo<\/strong><\/td>\n<td style=\"text-align: left;\">Ritmo de golpeteo irregular<\/td>\n<td style=\"text-align: left;\">Proyectil desgastado o ca\u00f1\u00f3n sucio<\/td>\n<td style=\"text-align: left;\">Inspeccione y limpie la pieza de mano.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Tacto<\/strong><\/td>\n<td style=\"text-align: left;\">Vibraci\u00f3n excesiva del mango<\/td>\n<td style=\"text-align: left;\">Juntas t\u00f3ricas de amortiguaci\u00f3n da\u00f1adas<\/td>\n<td style=\"text-align: left;\">Reemplace las juntas t\u00f3ricas de la pieza de mano.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Tacto<\/strong><\/td>\n<td style=\"text-align: left;\">Sobrecalentamiento de la pieza de mano<\/td>\n<td style=\"text-align: left;\">Uso excesivo continuo o ventilaci\u00f3n bloqueada<\/td>\n<td style=\"text-align: left;\">Permita tiempo de enfriamiento; revise las ventilaciones.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Vista<\/strong><\/td>\n<td style=\"text-align: left;\">Parpadeo de la pantalla<\/td>\n<td style=\"text-align: left;\">Inestabilidad de la fuente de alimentaci\u00f3n<\/td>\n<td style=\"text-align: left;\">Verifique el cable de alimentaci\u00f3n y el voltaje de salida.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Al prestar atenci\u00f3n a estas entradas sensoriales, puede detectar problemas como <strong>deriva de calibraci\u00f3n<\/strong>. Aqu\u00ed es donde la m\u00e1quina cree que est\u00e1 emitiendo un cierto nivel de energ\u00eda, pero la salida real es menor o mayor. Una salida alta debido a la deriva es peligrosa y puede causar hematomas, mientras que una salida baja hace que el tratamiento sea ineficaz.<\/p>\n<h2>\u00bfQu\u00e9 pasos de soluci\u00f3n de problemas debo seguir si mi m\u00e1quina de terapia de ondas de choque deja de funcionar?<\/h2>\n<p>Cuando solucionamos problemas con los clientes de forma remota, siempre comenzamos con lo b\u00e1sico para ahorrar tiempo y dinero antes de sugerir el reemplazo de piezas. El p\u00e1nico a menudo conduce a llamadas de servicio innecesarias para problemas simples.<\/p>\n<p><strong>Comience revisando la fuente de alimentaci\u00f3n, los fusibles y las conexiones del cable para descartar problemas el\u00e9ctricos. A continuaci\u00f3n, inspeccione la pieza de mano en busca de proyectiles atascados u juntas t\u00f3ricas desgastadas, y limpie los puertos de ventilaci\u00f3n. Si la pantalla no responde, realice un reinicio forzado antes de escalar a reparaciones internas.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/3-2-parts-detailed-photorealistic-close-disassembled-shockwave-therapy-mac-bab93830.jpg\" alt=\"Primer plano detallado de piezas desmontadas de m\u00e1quina de terapia de ondas de choque (ID#3)\" title=\"Piezas desmontadas\" \/><\/p>\n<p>Cuando su m\u00e1quina deja de funcionar, puede ser estresante. Sin embargo, un enfoque sistem\u00e1tico resuelve la mayor\u00eda de los problemas sin necesidad de enviar la m\u00e1quina de regreso a la f\u00e1brica. Aqu\u00ed est\u00e1 el proceso que recomendamos para nuestros socios.<br \/>\n<a href=\"https:\/\/www.ftc.gov\/business-guidance\/resources\/business-persons-guide-federal-warranty-law\">anula tu garant\u00eda<\/a> <sup><a href=\"#footnote-1\" id=\"ref-1\">1<\/a><\/sup><\/p>\n<h3>Paso 1: Comprobaci\u00f3n de la alimentaci\u00f3n y la conexi\u00f3n<\/h3>\n<p>Suena simple, pero los problemas de alimentaci\u00f3n representan un gran porcentaje de las \"aver\u00edas\".\"<\/p>\n<ol>\n<li><strong>Compruebe el fusible:<\/strong> La mayor\u00eda de las m\u00e1quinas profesionales tienen un compartimento para fusibles cerca de la toma de corriente. Si se produjo una sobretensi\u00f3n, es posible que el fusible se haya fundido para proteger los circuitos internos. Reempl\u00e1celo con el repuesto que normalmente se incluye en el paquete.<\/li>\n<li><strong>Inspeccione el cable de alimentaci\u00f3n:<\/strong> Busque da\u00f1os f\u00edsicos. Cambie el cable con otro dispositivo (como un monitor de computadora) para ver si la m\u00e1quina se enciende.<\/li>\n<li><strong>La prueba de \"mene\u00edto\":<\/strong> Mientras la m\u00e1quina est\u00e1 encendida (si es posible), mueva suavemente la conexi\u00f3n donde la pieza de mano se conecta a la unidad principal. Si la m\u00e1quina se apaga, es probable que los pines del conector est\u00e9n sueltos u oxidados.<\/li>\n<\/ol>\n<h3>Paso 2: Desatascar la pieza de mano<\/h3>\n<p>Para las m\u00e1quinas de ondas de choque neum\u00e1ticas, la falla mec\u00e1nica m\u00e1s com\u00fan es un proyectil atascado. Esto ocurre cuando el dispositivo no se limpia y el gel de acoplamiento o el polvo entran en el ca\u00f1\u00f3n.<\/p>\n<ul>\n<li><strong>S\u00edntoma:<\/strong> Escuchas que el compresor funciona, sale aire, pero no hay un impacto de onda de choque de \"golpeteo\".<\/li>\n<li><strong>Soluci\u00f3n:<\/strong> Abra la cabeza del aplicador. Retire el transmisor. Verifique si la bala (proyectil) se desliza libremente en el tubo. Si est\u00e1 atascada, es posible que necesite limpiar el tubo con el cepillo proporcionado o reemplazar el tubo por completo.<\/li>\n<li><strong>Advertencia:<\/strong> Nunca use aceite o grasa dentro de la pieza de mano a menos que se especifique. El aceite atrae el polvo y crea un lodo pegajoso que causa atascos.<\/li>\n<\/ul>\n<h3>Paso 3: Soluci\u00f3n de problemas de presi\u00f3n de aire<\/h3>\n<p>Si la m\u00e1quina se enciende pero no puede alcanzar alta presi\u00f3n (por ejemplo, le cuesta superar los 2 Bar), el problema suele ser el suministro de aire.<\/p>\n<ul>\n<li><strong>Verifique el Filtro:<\/strong> Normalmente hay una taza separadora de agua\/aceite en la parte posterior de la m\u00e1quina. Si est\u00e1 llena de agua, bloquea el flujo de aire. Vac\u00edela.<\/li>\n<li><strong>Escuche si hay fugas:<\/strong> Ponga la m\u00e1quina en espera. Si escucha un silbido, siga el sonido. Es posible que un simple conector de ajuste a presi\u00f3n solo necesite ser empujado de nuevo firmemente.<\/li>\n<\/ul>\n<h3>Paso 4: Restablecimiento del software<\/h3>\n<p>A veces, el software se congela debido a electricidad est\u00e1tica o fallos de memoria.<\/p>\n<ul>\n<li>Apague la m\u00e1quina en el interruptor principal.<\/li>\n<li>Desenchufe la m\u00e1quina de la pared.<\/li>\n<li>Espere 5 minutos. Esto permite que los condensadores de la placa base se descarguen por completo.<\/li>\n<li>Vuelva a enchufarla y reinicie.<\/li>\n<\/ul>\n<h3>Diagrama de flujo de soluci\u00f3n de problemas<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Problema<\/th>\n<th style=\"text-align: left;\">Causa probable<\/th>\n<th style=\"text-align: left;\">Primer paso<\/th>\n<th style=\"text-align: left;\">Segundo paso<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Sin energ\u00eda<\/strong><\/td>\n<td style=\"text-align: left;\">Fusible quemado \/ Cable defectuoso<\/td>\n<td style=\"text-align: left;\">Revisar\/Reemplazar fusible<\/td>\n<td style=\"text-align: left;\">Cambiar cable de alimentaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Sin impacto de onda de choque<\/strong><\/td>\n<td style=\"text-align: left;\">Proyectil atascado<\/td>\n<td style=\"text-align: left;\">Abrir pieza de mano y limpiar<\/td>\n<td style=\"text-align: left;\">Reemplazar proyectil\/tubo<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Error de baja presi\u00f3n<\/strong><\/td>\n<td style=\"text-align: left;\">Fuga de aire \/ Filtro obstruido<\/td>\n<td style=\"text-align: left;\">Vaciar separador de agua<\/td>\n<td style=\"text-align: left;\">Verificar conexiones de tuber\u00eda<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Error de sobrecalentamiento<\/strong><\/td>\n<td style=\"text-align: left;\">Ventilaciones bloqueadas<\/td>\n<td style=\"text-align: left;\">Mover la m\u00e1quina de la pared<\/td>\n<td style=\"text-align: left;\">Limpiar filtros de polvo<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Pantalla t\u00e1ctil congelada<\/strong><\/td>\n<td style=\"text-align: left;\">Fallo de software<\/td>\n<td style=\"text-align: left;\">Reinicio forzado (desenchufar)<\/td>\n<td style=\"text-align: left;\">Contactar soporte para firmware<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Si estos pasos no resuelven el problema, es probable que se trate de un fallo de un componente interno, como la fuente de alimentaci\u00f3n (PSU) o la v\u00e1lvula solenoide, que requiere intervenci\u00f3n profesional.<br \/>\n<a href=\"https:\/\/en.wikipedia.org\/wiki\/Short_circuit\">cortocircuito<\/a> <sup><a href=\"#footnote-2\" id=\"ref-2\">2<\/a><\/sup><\/p>\n<h2>\u00bfC\u00f3mo puedo prevenir aver\u00edas frecuentes en mi m\u00e1quina de terapia de ondas de choque?<\/h2>\n<p>Dise\u00f1amos nuestras m\u00e1quinas para que sean duraderas, pero el cuidado regular es el secreto de la longevidad en salones concurridos que atienden a m\u00faltiples pacientes al d\u00eda. La negligencia es la raz\u00f3n n\u00famero uno de fallo prematuro del equipo.<br \/>\n<a href=\"https:\/\/www.britannica.com\/technology\/compressor\">compresor de aire<\/a> <sup><a href=\"#footnote-3\" id=\"ref-3\">3<\/a><\/sup><\/p>\n<p><strong>Prevent malfunctions by implementing a strict maintenance schedule that includes daily cleaning of applicators and weekly checks of air filters. Regularly replace wear-and-tear parts like bullets and pipes according to the manufacturer&#8217;s usage count, and ensure the device is kept in a dust-free, well-ventilated environment.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/4-2-well-photorealistic-shockwave-therapy-machine-placed-ventilated-area-m-c404049f.jpg\" alt=\"M\u00e1quina de terapia de ondas de choque en un entorno de sala ventilada (ID#4)\" title=\"\u00c1rea ventilada\" \/><br \/>\n<a href=\"https:\/\/www.osha.gov\/electrostatic-discharge\">electricidad est\u00e1tica<\/a> <sup><a href=\"#footnote-4\" id=\"ref-4\">4<\/a><\/sup><\/p>\n<p>La prevenci\u00f3n siempre es m\u00e1s barata que la reparaci\u00f3n. En nuestra experiencia, las cl\u00ednicas que siguen un estricto protocolo de mantenimiento extienden la vida \u00fatil de sus m\u00e1quinas durante a\u00f1os en comparaci\u00f3n con las que no lo hacen. Aqu\u00ed le mostramos c\u00f3mo mantener su m\u00e1quina funcionando como nueva.<br \/>\n<a href=\"https:\/\/www.sciencedirect.com\/topics\/engineering\/oil-water-separator\">separador de agua\/aceite<\/a> <sup><a href=\"#footnote-5\" id=\"ref-5\">5<\/a><\/sup><\/p>\n<h3>Gestione sus consumibles estrictamente<\/h3>\n<p>Las piezas de mano de onda de choque son art\u00edculos consumibles. Contienen partes m\u00f3viles (balas\/proyectiles) que golpean un transmisor de metal millones de veces. Se desgastar\u00e1n.<\/p>\n<ul>\n<li><strong>Rastrea el recuento de disparos:<\/strong> La mayor\u00eda de las m\u00e1quinas muestran un \"recuento total de disparos\". Conoce la vida \u00fatil de las piezas de tu pieza de mano (generalmente de 1 a 2 millones de disparos).<\/li>\n<li><strong>Reemplaza antes de que falle:<\/strong> No esperes a que la bala se rompa dentro del mango. Una bala rota puede rayar el tubo interior, arruinando todo el cuerpo de la pieza de mano. Reemplaza el kit de bala y tubo de forma proactiva cuando alcances el recuento de disparos recomendado.<\/li>\n<\/ul>\n<h3>Control Ambiental<\/h3>\n<p>El calor y el polvo son enemigos de los equipos de belleza electr\u00f3nicos.<\/p>\n<ul>\n<li><strong>Ventilaci\u00f3n:<\/strong> El compresor de aire genera un calor considerable. Aseg\u00farate de que la m\u00e1quina tenga al menos 20 cm de espacio libre con respecto a las paredes o muebles. Nunca cubras las rejillas de ventilaci\u00f3n con toallas.<\/li>\n<li><strong>Gesti\u00f3n del polvo:<\/strong> Los ventiladores aspiran polvo, que recubre las placas de circuito internas y provoca sobrecalentamiento. En un entorno de sal\u00f3n, el spray para el cabello y el polvo pueden crear un residuo pegajoso. Limpia los filtros de aire externos semanalmente.<\/li>\n<\/ul>\n<h3>Rutina de limpieza diaria y semanal<\/h3>\n<p>La acumulaci\u00f3n de gel es una causa importante de fallos. El gel de ultrasonido es conductor y puede corroer los conectores si gotea en lugares equivocados.<\/p>\n<ul>\n<li><strong>Despu\u00e9s de cada tratamiento:<\/strong> Limpia la cabeza del transmisor. Elimina todo residuo de gel.<\/li>\n<li><strong>Fin del d\u00eda:<\/strong> Desenrosque la cabeza del transmisor. Verifique si el gel se ha filtrado en el cilindro. Si es as\u00ed, l\u00edmpielo inmediatamente. El gel dentro del cilindro hace que el proyectil se atasque.<\/li>\n<li><strong>Semanalmente:<\/strong> Inspeccione el cable de alimentaci\u00f3n y el cable de la pieza de mano en busca de grietas. Si ve los cables internos a trav\u00e9s de la carcasa de goma, reemplace el cable inmediatamente para evitar cortocircuitos.<\/li>\n<\/ul>\n<h3>Lista de verificaci\u00f3n del programa de mantenimiento<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Frecuencia<\/th>\n<th style=\"text-align: left;\">Tarea<\/th>\n<th style=\"text-align: left;\">Objetivo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Diario<\/strong><\/td>\n<td style=\"text-align: left;\">Limpiar la cabeza del transmisor y quitar el gel<\/td>\n<td style=\"text-align: left;\">Prevenir la corrosi\u00f3n y el atasco<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Semanal<\/strong><\/td>\n<td style=\"text-align: left;\">Revisar la taza del separador de agua<\/td>\n<td style=\"text-align: left;\">Asegurar aire seco para el compresor<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Semanal<\/strong><\/td>\n<td style=\"text-align: left;\">Inspeccionar los cables en busca de da\u00f1os f\u00edsicos<\/td>\n<td style=\"text-align: left;\">Prevenir cortocircuitos el\u00e9ctricos<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Mensual<\/strong><\/td>\n<td style=\"text-align: left;\">Limpiar los filtros de admisi\u00f3n de aire<\/td>\n<td style=\"text-align: left;\">Prevenir el sobrecalentamiento<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Trimestralmente<\/strong><\/td>\n<td style=\"text-align: left;\">Revisar las estad\u00edsticas del recuento de disparos<\/td>\n<td style=\"text-align: left;\">Planificar el reemplazo de consumibles<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Anualmente<\/strong><\/td>\n<td style=\"text-align: left;\">Calibraci\u00f3n profesional<\/td>\n<td style=\"text-align: left;\">Asegurar una salida de energ\u00eda precisa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>La importancia del \"descanso\"<\/h3>\n<p>Incluso las m\u00e1quinas robustas necesitan enfriarse. Si tiene clientes uno tras otro, intente dejar 5-10 minutos entre tratamientos. Esto permite que el compresor se enfr\u00ede y que la pieza de mano disipe el calor. Disparar continuamente durante una hora sin descanso puede sobrecalentar la bobina o las juntas t\u00f3ricas, lo que lleva a una r\u00e1pida degradaci\u00f3n del rendimiento.<\/p>\n<h2>\u00bfCu\u00e1ndo debo contactar a mi proveedor para obtener ayuda con problemas de la m\u00e1quina de terapia de ondas de choque?<\/h2>\n<p>Nuestro equipo de soporte aconseja contactarnos inmediatamente cuando se activen los mecanismos de seguridad o aparezcan errores internos, en lugar de arriesgarse a sufrir m\u00e1s da\u00f1os. Intentar solucionar problemas el\u00e9ctricos complejos por su cuenta puede ser peligroso.<br \/>\n<a href=\"https:\/\/www.sciencedirect.com\/topics\/medicine-and-dentistry\/ultrasound-gel\">gel de acoplamiento<\/a> <sup><a href=\"#footnote-6\" id=\"ref-6\">6<\/a><\/sup><\/p>\n<p><strong>P\u00f3ngase en contacto con su proveedor inmediatamente si encuentra c\u00f3digos de error persistentes, humo u olores a quemado, que indican fallos el\u00e9ctricos internos graves. Tambi\u00e9n debe buscar soporte profesional si la soluci\u00f3n de problemas b\u00e1sicos no logra restaurar la presi\u00f3n o si el dispositivo requiere una calibraci\u00f3n interna que anule la garant\u00eda si la realiza usted mismo.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/5-2-warning-dramatic-photorealistic-close-shockwave-therapy-machine-contro-56647c0c.jpg\" alt=\"Pantalla de advertencia primer plano en m\u00e1quina de terapia de ondas de choque (ID#5)\" title=\"Pantalla de advertencia\" \/><br \/>\n<a href=\"https:\/\/www.energy.gov\/ceser\/activities\/energy-security\/power-outages-and-surges\">se produjo una sobretensi\u00f3n<\/a> <sup><a href=\"#footnote-7\" id=\"ref-7\">7<\/a><\/sup><\/p>\n<p>Saber cu\u00e1ndo dejar de solucionar problemas y pedir ayuda es una habilidad cr\u00edtica. Si bien alentamos el mantenimiento b\u00e1sico, hay una l\u00ednea que no debe cruzar. Cruzar esta l\u00ednea puede anular su garant\u00eda y poner en riesgo a su personal o pacientes.<br \/>\n<a href=\"https:\/\/www.ispe.org\/pharmaceutical-engineering\/ispe-pharmaceutical-engineering-magazine\/2011-volume-31-issue-4\/calibration-drift\">deriva de calibraci\u00f3n<\/a> <sup><a href=\"#footnote-8\" id=\"ref-8\">8<\/a><\/sup><\/p>\n<h3>La zona \"No tocar\"<\/h3>\n<p>Hay s\u00edntomas espec\u00edficos que se\u00f1alan un fallo cr\u00edtico. Si los ve, desenchufe la m\u00e1quina y p\u00f3ngase en contacto con nosotros (o su proveedor) inmediatamente:<\/p>\n<ol>\n<li><strong>Olor a quemado o humo:<\/strong> Esto indica un cortocircuito, probablemente en la fuente de alimentaci\u00f3n o en el motor del compresor. Volver a encenderlo puede provocar un incendio.<\/li>\n<li><strong>Ruidos fuertes de chirrido:<\/strong> Si el compresor suena como metal rozando metal, un pist\u00f3n o un rodamiento ha fallado. Seguir haci\u00e9ndolo destruir\u00e1 el motor por completo.<\/li>\n<li><strong>Entrada de l\u00edquido:<\/strong> Si se ha derramado agua o gel <em>dentro<\/em> el chasis principal de la m\u00e1quina. No la encienda.<\/li>\n<\/ol>\n<h3>Consideraciones de garant\u00eda<\/h3>\n<p>La mayor\u00eda de los fabricantes, incluidos nosotros, tienen sellos de garant\u00eda en los tornillos del chasis principal. Romper estos sellos para \"echar un vistazo\" anular\u00e1 su garant\u00eda.<\/p>\n<ul>\n<li><strong>Bricolaje permitido:<\/strong> Cambiar las puntas de la pieza de mano, limpiar filtros, cambiar fusibles.<\/li>\n<li><strong>Bricolaje prohibido:<\/strong> Abrir la carcasa principal de la m\u00e1quina, soldar cables, modificar el software.<\/li>\n<\/ul>\n<h3>C\u00f3mo prepararse para una llamada de soporte<\/h3>\n<p>To get the fastest solution, you need to provide your supplier with clear information. &quot;It&#8217;s not working&quot; is too vague and leads to long email exchanges.<\/p>\n<ul>\n<li><strong>Grabar un video:<\/strong> Un video de 15 segundos que muestre el c\u00f3digo de error, el sonido que hace la m\u00e1quina o la falta de impacto vale m\u00e1s que mil palabras. Env\u00ede esto por WhatsApp o correo electr\u00f3nico.<\/li>\n<li><strong>N\u00famero de serie:<\/strong> Tenga lista la foto de la etiqueta trasera. Esto le dice al fabricante exactamente qu\u00e9 lote y componentes se utilizaron en su m\u00e1quina.<\/li>\n<li><strong>Descripci\u00f3n detallada:<\/strong> Instead of &quot;it&#8217;s broken,&quot; say &quot;The machine turns on, the compressor runs, but the handpiece does not strike, and Error 04 is on the screen.&quot;<\/li>\n<\/ul>\n<h3>Matriz de bricolaje vs. servicio profesional<\/h3>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Problema<\/th>\n<th style=\"text-align: left;\">Acci\u00f3n<\/th>\n<th style=\"text-align: left;\">\u00bfQui\u00e9n lo arregla?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Bala\/Tubo desgastado<\/strong><\/td>\n<td style=\"text-align: left;\">Reemplazar con kit de repuesto<\/td>\n<td style=\"text-align: left;\"><strong>Usuario (Usted)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Fusible quemado<\/strong><\/td>\n<td style=\"text-align: left;\">Reemplazar fusible<\/td>\n<td style=\"text-align: left;\"><strong>Usuario (Usted)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Filtro obstruido<\/strong><\/td>\n<td style=\"text-align: left;\">Limpiar o reemplazar<\/td>\n<td style=\"text-align: left;\"><strong>Usuario (Usted)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Error de software<\/strong><\/td>\n<td style=\"text-align: left;\">Actualizaci\u00f3n remota \/ Restablecer<\/td>\n<td style=\"text-align: left;\"><strong>Gu\u00eda del usuario + proveedor<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Fallo de alimentaci\u00f3n interna<\/strong><\/td>\n<td style=\"text-align: left;\">Reemplazar fuente de alimentaci\u00f3n<\/td>\n<td style=\"text-align: left;\"><strong>Proveedor \/ T\u00e9cnico<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Fallo del compresor<\/strong><\/td>\n<td style=\"text-align: left;\">Reemplazar motor<\/td>\n<td style=\"text-align: left;\"><strong>Proveedor \/ T\u00e9cnico<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Fallo de pantalla<\/strong><\/td>\n<td style=\"text-align: left;\">Reemplazar m\u00f3dulo de pantalla<\/td>\n<td style=\"text-align: left;\"><strong>Proveedor \/ T\u00e9cnico<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>By understanding these boundaries, you ensure that small problems don&#8217;t become expensive disasters. We are here to support your business, and clear communication helps us get your clinic back up and running faster.<br \/>\n<a href=\"https:\/\/www.physio-pedia.com\/Extracorporeal_Shockwave_Therapy_(ESWT)\">problema de tolerancia del paciente<\/a> <sup><a href=\"#footnote-9\" id=\"ref-9\">9<\/a><\/sup><\/p>\n<h2>Conclusi\u00f3n<\/h2>\n<p>El mantenimiento regular y la resoluci\u00f3n r\u00e1pida de problemas garantizan que su m\u00e1quina de terapia de ondas de choque siga siendo un activo rentable para su negocio. Al detectar problemas a tiempo y saber cu\u00e1ndo pedir ayuda, protege su inversi\u00f3n y a sus pacientes.<br \/>\n<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3438864\/\">m\u00e1quina de ondas de choque neum\u00e1ticas<\/a> <sup><a href=\"#footnote-10\" id=\"ref-10\">10<\/a><\/sup><br \/>\n<a href=\"https:\/\/www.physio-pedia.com\/Extracorporeal_Shockwave_Therapy_(ESWT)\">problema de tolerancia del paciente<\/a> <sup><a href=\"#footnote-9\" id=\"ref-9\">9<\/a><\/sup><\/p>\n<h2>Notas al pie<\/h2>\n<p><span id=\"footnote-1\"><\/p>\n<ol>\n<li>Hace referencia a las normas legales relativas a los t\u00e9rminos de garant\u00eda y las reparaciones no autorizadas. <a href=\"#ref-1\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-2\"><\/p>\n<ol start=\"2\">\n<li>Define la falla el\u00e9ctrica peligrosa indicada por olores a quemado. <a href=\"#ref-2\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-3\"><\/p>\n<ol start=\"3\">\n<li>Provides technical details on the machine&#8217;s primary heat-generating component. <a href=\"#ref-3\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-4\"><\/p>\n<ol start=\"4\">\n<li>Explica la causa del bloqueo del software que requiere un reinicio. <a href=\"#ref-4\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-5\"><\/p>\n<ol start=\"5\">\n<li>Resumen t\u00e9cnico del componente de filtraci\u00f3n mencionado en la resoluci\u00f3n de problemas. <a href=\"#ref-5\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-6\"><\/p>\n<ol start=\"6\">\n<li>Describe las propiedades del medio que pueden causar atascos internos. <a href=\"#ref-6\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-7\"><\/p>\n<ol start=\"7\">\n<li>Explica el fen\u00f3meno el\u00e9ctrico responsable de quemar fusibles. <a href=\"#ref-7\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-8\"><\/p>\n<ol start=\"8\">\n<li>Define el concepto t\u00e9cnico de deriva de la medici\u00f3n del instrumento a lo largo del tiempo. <a href=\"#ref-8\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-9\"><\/p>\n<ol start=\"9\">\n<li>Contextualiza la sensaci\u00f3n t\u00edpica del paciente y los niveles de tolerancia durante la terapia. <a href=\"#ref-9\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-10\"><\/p>\n<ol start=\"10\">\n<li>Proporciona antecedentes cient\u00edficos sobre c\u00f3mo funciona la generaci\u00f3n de ondas de choque neum\u00e1ticas. <a href=\"#ref-10\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>At KMSLASER, we understand that a broken machine means cancelled appointments and lost revenue for your clinic. Downtime is frustrating, but knowing the signs of failure early can save your business. Common malfunctions include pressure sensor failures, handpiece wear, power supply issues, and software glitches. Solutions involve calibrating sensors, replacing worn bullets or springs, checking [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":8789,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[60],"tags":[],"class_list":["post-8793","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-shockwave-therapy-machine"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions? - KMSLaser<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kmslaser.com\/es\/cuales-son-las-averias-comunes-de-las-maquinas-de-terapia-de-ondas-de-choque-y-sus-soluciones-correspondientes\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions?\" \/>\n<meta property=\"og:description\" content=\"At KMSLASER, we understand that a broken machine means cancelled appointments and lost revenue for your clinic. Downtime is frustrating, but knowing the signs of failure early can save your business. Common malfunctions include pressure sensor failures, handpiece wear, power supply issues, and software glitches. Solutions involve calibrating sensors, replacing worn bullets or springs, checking [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kmslaser.com\/es\/cuales-son-las-averias-comunes-de-las-maquinas-de-terapia-de-ondas-de-choque-y-sus-soluciones-correspondientes\/\" \/>\n<meta property=\"og:site_name\" content=\"KMSLaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-23T14:22:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-10T14:25:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sophia Wu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sophia Wu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/\"},\"author\":{\"name\":\"Sophia Wu\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\"},\"headline\":\"What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions?\",\"datePublished\":\"2025-12-23T14:22:14+00:00\",\"dateModified\":\"2026-01-10T14:25:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/\"},\"wordCount\":2409,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg\",\"articleSection\":[\"Shockwave Therapy Machine\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/\",\"name\":\"What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions? - KMSLaser\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg\",\"datePublished\":\"2025-12-23T14:22:14+00:00\",\"dateModified\":\"2026-01-10T14:25:50+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#primaryimage\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg\",\"width\":600,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/kmslaser.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"name\":\"KMSLaser\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/kmslaser.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\",\"name\":\"KMSLaser\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"width\":180,\"height\":71,\"caption\":\"KMSLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\",\"name\":\"Sophia Wu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"caption\":\"Sophia Wu\"},\"url\":\"https:\\\/\\\/kmslaser.com\\\/es\\\/author\\\/sophia\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u00bfCu\u00e1les son las aver\u00edas comunes de las m\u00e1quinas de terapia de ondas de choque y sus soluciones correspondientes? - KMSLaser","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kmslaser.com\/es\/cuales-son-las-averias-comunes-de-las-maquinas-de-terapia-de-ondas-de-choque-y-sus-soluciones-correspondientes\/","og_locale":"es_MX","og_type":"article","og_title":"What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions?","og_description":"At KMSLASER, we understand that a broken machine means cancelled appointments and lost revenue for your clinic. Downtime is frustrating, but knowing the signs of failure early can save your business. Common malfunctions include pressure sensor failures, handpiece wear, power supply issues, and software glitches. Solutions involve calibrating sensors, replacing worn bullets or springs, checking [&hellip;]","og_url":"https:\/\/kmslaser.com\/es\/cuales-son-las-averias-comunes-de-las-maquinas-de-terapia-de-ondas-de-choque-y-sus-soluciones-correspondientes\/","og_site_name":"KMSLaser","article_published_time":"2025-12-23T14:22:14+00:00","article_modified_time":"2026-01-10T14:25:50+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg","type":"image\/jpeg"}],"author":"Sophia Wu","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Sophia Wu","Tiempo de lectura":"12 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#article","isPartOf":{"@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/"},"author":{"name":"Sophia Wu","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588"},"headline":"What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions?","datePublished":"2025-12-23T14:22:14+00:00","dateModified":"2026-01-10T14:25:50+00:00","mainEntityOfPage":{"@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/"},"wordCount":2409,"commentCount":0,"publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"image":{"@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg","articleSection":["Shockwave Therapy Machine"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/","url":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/","name":"\u00bfCu\u00e1les son las aver\u00edas comunes de las m\u00e1quinas de terapia de ondas de choque y sus soluciones correspondientes? - KMSLaser","isPartOf":{"@id":"https:\/\/kmslaser.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#primaryimage"},"image":{"@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg","datePublished":"2025-12-23T14:22:14+00:00","dateModified":"2026-01-10T14:25:50+00:00","breadcrumb":{"@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#primaryimage","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/12\/2-1-machine-photorealistic-capturing-moment-diagnostic-observation-profess-7497b4e2.jpg","width":600,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/kmslaser.com\/what-are-the-common-malfunctions-of-shockwave-therapy-machines-and-their-corresponding-solutions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/kmslaser.com\/"},{"@type":"ListItem","position":2,"name":"What are the common malfunctions of Shockwave Therapy Machines and their corresponding solutions?"}]},{"@type":"WebSite","@id":"https:\/\/kmslaser.com\/#website","url":"https:\/\/kmslaser.com\/","name":"KMSLaser","description":"","publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kmslaser.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/kmslaser.com\/#organization","name":"KMSLaser","url":"https:\/\/kmslaser.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","width":180,"height":71,"caption":"KMSLaser"},"image":{"@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588","name":"Sophia Wu","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","caption":"Sophia Wu"},"url":"https:\/\/kmslaser.com\/es\/author\/sophia\/"}]}},"_links":{"self":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/posts\/8793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/comments?post=8793"}],"version-history":[{"count":0,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/posts\/8793\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/media\/8789"}],"wp:attachment":[{"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/media?parent=8793"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/categories?post=8793"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kmslaser.com\/es\/wp-json\/wp\/v2\/tags?post=8793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}