{"id":8380,"date":"2025-11-18T23:14:27","date_gmt":"2025-11-18T23:14:27","guid":{"rendered":"https:\/\/kmslaser.com\/?p=8380"},"modified":"2025-11-18T23:14:27","modified_gmt":"2025-11-18T23:14:27","slug":"wie-hoch-ist-der-dezibel-larmpegel-des-stoswellentherapiegerats","status":"publish","type":"post","link":"https:\/\/kmslaser.com\/de\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/","title":{"rendered":"Wie hoch ist der Dezibel-L\u00e4rmpegel des Sto\u00dfwellentherapieger\u00e4ts?"},"content":{"rendered":"<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/1a-high-end-3d-rendered-illustration-showing-a-shoc.jpg\" alt=\"Sto\u00dfwellentherapieger\u00e4t bereit auf dem Behandlungstisch der Klinik (ID#1)\" class=\"top-image-square\">\n<\/p>\n<p>Als Hersteller erhalte ich oft Fragen, ob Sto\u00dfwellentherapieger\u00e4te f\u00fcr den klinischen Einsatz \u201czu laut\u201d sind. Unsere Tests best\u00e4tigen, dass der akustische Impuls zwar deutlich wahrnehmbar ist, die L\u00e4rmbelastung jedoch bei bestimmungsgem\u00e4\u00dfer Verwendung innerhalb der anerkannten Arbeitsschutzgrenzwerte liegt.<\/p>\n<p><strong>Sto\u00dfwellentherapieger\u00e4te erzeugen typischerweise Impulsger\u00e4usche zwischen 75 dB und 90 dB, abh\u00e4ngig von Ger\u00e4tetyp, Frequenz und Energieeinstellung. Radiale pneumatische Ger\u00e4te tendieren zum oberen Bereich (85\u201390 dB), w\u00e4hrend fokussierte elektromagnetische Systeme normalerweise n\u00e4her bei 75\u201385 dB arbeiten.<\/strong><br \/>\nDas Verst\u00e4ndnis dieser Schallpegel hilft Kliniken, komfortable, konforme Arbeitsbereiche im Einklang mit <a href=\"https:\/\/www.osha.gov\/noise\">Richtlinien zur L\u00e4rmbelastung am Arbeitsplatz<\/a> <sup><a href=\"#footnote-1\" id=\"ref-1\">1<\/a><\/sup>.<\/p>\n<hr \/>\n<h2>Wie wirkt sich Maschinenl\u00e4rm auf den Patientenkomfort und das Personalumfeld in Kliniken aus?<\/h2>\n<p>Das \u201cKnack\u201d-Ger\u00e4usch eines Sto\u00dfwellenimpulses ist kurz und rhythmisch. Patienten beschreiben es oft als \u00e4hnlich wie Klopfen oder Trommeln. Obwohl transient, kann wiederholte Exposition leichte Beschwerden oder Ablenkungen verursachen, insbesondere in ruhigen Behandlungsumgebungen, insbesondere wenn man die <a href=\"https:\/\/en.wikipedia.org\/wiki\/Sound_pressure\">Prinzipien der Schalldruckwahrnehmung<\/a> <sup><a href=\"#footnote-2\" id=\"ref-2\">2<\/a><\/sup>.<\/p>\n<p><strong>L\u00e4rm beeintr\u00e4chtigt sowohl die Patientenentspannung als auch die Erm\u00fcdung des Personals. W\u00e4hrend kurzfristige Sitzungen selten Geh\u00f6rsch\u00e4den verursachen, kann wiederholte Exposition nahe 85\u201390 dB Schutzma\u00dfnahmen oder akustische Minderung in stark frequentierten Kliniken rechtfertigen, im Einklang mit den empfohlenen <a href=\"https:\/\/www.cdc.gov\/niosh\/topics\/noise\/\">Geh\u00f6rschutzpraktiken<\/a> <sup><a href=\"#footnote-3\" id=\"ref-3\">3<\/a><\/sup>.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2a-realistic-treatment-room-scene-showing-a-patient.jpg\" alt=\"Kliniker f\u00fchrt akustische Wellentherapie an entspanntem Patienten in einem schallged\u00e4mmten Raum durch (ID#2)\" title=\"Akustische Therapiebehandlung\" \/><\/p>\n<h3>\u00dcberblick \u00fcber die Auswirkungen<\/h3>\n<ul>\n<li><strong>Patientenkomfort:<\/strong> H\u00f6here Frequenzen (20\u201325 Hz) k\u00f6nnen lauter und erschreckender wirken.  <\/li>\n<li><strong>Erm\u00fcdung des Behandlers:<\/strong> Bediener, die sich in der N\u00e4he des Handst\u00fccks aufhalten, sind einer kumulativen t\u00e4glichen L\u00e4rmbelastung ausgesetzt.  <\/li>\n<li><strong>Akustische Reflexion:<\/strong> R\u00e4ume mit harten B\u00f6den oder W\u00e4nden verst\u00e4rken die wahrgenommene Lautst\u00e4rke pro Grundeinheit <a href=\"https:\/\/www.nti-audio.com\/en\/support\/know-how\/room-acoustics-basics\">Raumakustisches Verhalten<\/a> <sup><a href=\"#footnote-4\" id=\"ref-4\">4<\/a><\/sup>.  <\/li>\n<\/ul>\n<h3>Tabelle 1 \u2013 L\u00e4rmwahrnehmung im klinischen Betrieb<\/h3>\n<table>\n<thead>\n<tr>\n<th>Einstellungfaktor<\/th>\n<th>L\u00e4rmwirkung<\/th>\n<th>Abmilderung<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kleiner geschlossener Raum<\/td>\n<td>Nachhall \u2191<\/td>\n<td>Akustikpaneele installieren<\/td>\n<\/tr>\n<tr>\n<td>Mehrere Ger\u00e4te im selben Raum<\/td>\n<td>\u00dcberlappung \u2191<\/td>\n<td>Zeitliche Trennung nutzen<\/td>\n<\/tr>\n<tr>\n<td>Hochfrequenzprotokolle<\/td>\n<td>Pulszahl \u2191<\/td>\n<td>Geh\u00f6rschutz anbieten<\/td>\n<\/tr>\n<tr>\n<td>Empfindliche Patienten<\/td>\n<td>Stress \u2191<\/td>\n<td>Gew\u00f6hnungsphase zulassen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Was ist der typische Ger\u00e4uschpegel (dB) w\u00e4hrend des Betriebs f\u00fcr radiale im Vergleich zu fokussierten Ger\u00e4ten?<\/h2>\n<p>Verschiedene Technologien erzeugen auf unterschiedliche Weise Ger\u00e4usche. Pneumatische (radiale) Systeme sto\u00dfen Druckluft gegen ein internes Projektil aus, w\u00e4hrend fokussierte Systeme elektromagnetische oder piezoelektrische Treiber verwenden \u2013 leiser, aber sch\u00e4rfer im Ton.<\/p>\n<p><strong>Typische radiale Sto\u00dfwellensysteme messen 85\u201390 dB in 1 m Entfernung bei maximaler Energie; fokussierte Systeme liegen im Durchschnitt bei 75\u201385 dB. Umgebungsreflexionen und das Design des Maschinengeh\u00e4uses k\u00f6nnen die Messwerte um \u00b13 dB verschieben.<\/strong><br \/>\nDiese Metriken stimmen mit <a href=\"https:\/\/www.noisemeters.com\/help\/faq\/decibel\/\">A-bewertete Dezibelmessung<\/a> <sup><a href=\"#footnote-5\" id=\"ref-5\">5<\/a><\/sup> \u00fcberein, die in der Akustik von Medizinprodukten verwendet wird.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/3a-photorealistic-digital-image-showing-an-engineer.jpg\" alt=\"Ingenieur misst akustische Pegel in einer Schalltotkammer f\u00fcr medizinische Ger\u00e4te (ID#3)\" title=\"Schalltotkammer-Tests\" \/><\/p>\n<h3>Tabelle 2 \u2013 Gemessene L\u00e4rmpegel nach Technologieart<\/h3>\n<table>\n<thead>\n<tr>\n<th>Ger\u00e4tetyp<\/th>\n<th>Mechanismus<\/th>\n<th>Typischer L\u00e4rm (dB A)<\/th>\n<th>Messabstand<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Radial pneumatisch<\/td>\n<td>Luftgetriebenes Projektil<\/td>\n<td>85\u201390<\/td>\n<td>1 m<\/td>\n<\/tr>\n<tr>\n<td>Elektromagnetisch fokussiert<\/td>\n<td>Spulengesteuerter akustischer Impuls<\/td>\n<td>78\u201385<\/td>\n<td>1 m<\/td>\n<\/tr>\n<tr>\n<td>Piezoelektrisch fokussiert<\/td>\n<td>Kristallarray-Impuls<\/td>\n<td>75\u201382<\/td>\n<td>1 m<\/td>\n<\/tr>\n<tr>\n<td>Tragbare\/Heimmodelle<\/td>\n<td>Niederdruckvarianten<\/td>\n<td>70\u201380<\/td>\n<td>1 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Wie sollten K\u00e4ufer L\u00e4rmpegelmessungen oder Lieferantendokumentationen anfordern?<\/h2>\n<p>Die Ger\u00e4uschpr\u00fcfung f\u00fcr Sto\u00dfwellenger\u00e4te ist nicht universell standardisiert, aber namhafte Hersteller f\u00fchren <strong>ISO 3744\/3746 Schalldruckmessungen<\/strong> oder gleichwertige Messungen unter kontrollierten Laborbedingungen durch, die auf <a href=\"https:\/\/www.iso.org\/standard\/50652.html\">internationalen akustischen Pr\u00fcfnormen basieren<\/a> <sup><a href=\"#footnote-6\" id=\"ref-6\">6<\/a><\/sup>.<\/p>\n<p><strong>K\u00e4ufer sollten externe oder interne akustische Pr\u00fcfberichte anfordern, die den Schalldruckpegel (SPL in dB A), die Messmethode und den Messabstand angeben. Lieferantenantworten sollten Rohdaten oder Zertifizierungsreferenzen zur \u00dcberpr\u00fcfung enthalten.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/4a-professional-workspace-scene-where-a-buyer-exami.jpg\" alt=\"Qualit\u00e4tsmanager pr\u00fcft ISO-Konformit\u00e4tsberichte f\u00fcr die Herstellung von Sch\u00f6nheitsger\u00e4ten (ID#4)\" title=\"ISO-Konformit\u00e4tspr\u00fcfung\" \/><\/p>\n<h3>Tabelle 3 \u2014 Checkliste f\u00fcr K\u00e4ufer zur \u00dcberpr\u00fcfung der L\u00e4rmdokumentation<\/h3>\n<table>\n<thead>\n<tr>\n<th>Anforderung<\/th>\n<th>Warum es wichtig ist<\/th>\n<th>Erwartete Daten<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Messstandard<\/td>\n<td>Best\u00e4tigt wiederholbare Methode<\/td>\n<td>ISO 3744 \/ IEC 61672<\/td>\n<\/tr>\n<tr>\n<td>Energie-\/Frequenzbedingung<\/td>\n<td>L\u00e4rm skaliert mit Energie<\/td>\n<td>Testparameter berichten<\/td>\n<\/tr>\n<tr>\n<td>Abstand von der Quelle<\/td>\n<td>Entscheidend f\u00fcr den Vergleich<\/td>\n<td>Normalerweise 1 m<\/td>\n<\/tr>\n<tr>\n<td>Spitzenwert vs. \u00e4quivalenter SPL<\/td>\n<td>Impuls vs. kontinuierlich<\/td>\n<td>Beide Werte, falls verf\u00fcgbar<\/td>\n<\/tr>\n<tr>\n<td>Beschreibung der Umgebung<\/td>\n<td>Raumakustik beeinflusst Ergebnisse<\/td>\n<td>Hallraum oder klinischer Raum<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Gibt es Branchenrichtlinien f\u00fcr akzeptable L\u00e4rmpegel f\u00fcr Therapieger\u00e4te?<\/h2>\n<p>Obwohl es keinen ESWT-spezifischen EU- oder ISO-Standard f\u00fcr die L\u00e4rmemission gibt, verweisen allgemeine medizinisch-elektrische Sicherheitsstandards indirekt auf akzeptable Schallbelastung.<\/p>\n<p><strong>Die meisten Kliniken halten sich an die Arbeitsschutzrichtlinien f\u00fcr L\u00e4rm, die eine t\u00e4gliche Exposition von \u2264 85 dB A f\u00fcr das Personal und einen Spitzenwert von \u2264 90 dB A an der Patientenposition empfehlen. Hersteller halten sich an die ergonomischen Klauseln der IEC 60601-1, die eine Risikobewertung von akustischem Unbehagen erfordern.<\/strong><\/p>\n<p>1. Dazu geh\u00f6ren die EU-Richtlinie <a href=\"https:\/\/osha.europa.eu\/en\/legislation\/directive\/2003-10-ec\">2. 2003\/10\/EG \u00fcber den L\u00e4rmschutz f\u00fcr Arbeitnehmer<\/a> <sup><a href=\"#footnote-7\" id=\"ref-7\">7<\/a><\/sup>, 3. , die L\u00e4rmschutzvorschriften der OSHA <a href=\"https:\/\/www.osha.gov\/noise\/standards\">4. , die Empfehlungen der WHO<\/a> <sup><a href=\"#footnote-8\" id=\"ref-8\">8<\/a><\/sup>, 5. , sowie klinische Leitlinien von ISMST und Physiotherapieverb\u00e4nden. <a href=\"https:\/\/www.who.int\/publications\/i\/item\/9789289053563\">Richtlinien f\u00fcr Umgebungsger\u00e4usche<\/a> <sup><a href=\"#footnote-9\" id=\"ref-9\">9<\/a><\/sup>, 6. Sto\u00dfwellentherapieger\u00e4te emittieren.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/5a-professional-infographic-highlighting-occupation.jpg\" alt=\"Krankenhaus-MRT-Raum mit L\u00e4rmbelastungssicherheitshinweis f\u00fcr Personal und Patienten (ID#5)\" title=\"MRI-L\u00e4rmsicherheitsrichtlinie\" \/><\/p>\n<hr \/>\n<h2>Schlussfolgerung<\/h2>\n<p>7. 75\u201390 dB <strong>8. Impulsl\u00e4rm, abh\u00e4ngig von Technologie und Energieniveau. Dieser Schall ist unter regulierter Exposition sicher, kann aber Komfort und Konzentration beeintr\u00e4chtigen.<\/strong> 9. Kliniken sollten die akustische Gestaltung bewerten, die Testdaten des Lieferanten \u00fcberpr\u00fcfen und grundlegenden Geh\u00f6rschutz f\u00fcr den Betrieb mit hoher Frequenz und hohem Volumen in Betracht ziehen, im Einklang mit weltweit anerkannten.<br \/>\n10. L\u00e4rmrisikomanagementpraktiken <a href=\"https:\/\/www.hse.gov.uk\/noise\/index.htm\">11. 1. OSHA-Leitlinien zu Grenzwerten f\u00fcr L\u00e4rmbelastung am Arbeitsplatz.<\/a> <sup><a href=\"#footnote-10\" id=\"ref-10\">10<\/a><\/sup>.<\/p>\n<hr \/>\n<h2>Fu\u00dfnoten<\/h2>\n<p><span id=\"footnote-1\">12. 2. \u00dcberblick \u00fcber die Schallphysiologie, die die menschliche Wahrnehmung beeinflusst. <a href=\"#ref-1\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-2\">13. 3. NIOSH-Empfehlungen zur Verhinderung von Geh\u00f6rsch\u00e4den durch L\u00e4rm am Arbeitsplatz. <a href=\"#ref-2\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-3\">14. 4. Einf\u00fchrung in Raumakustik und Schallreflexionen. <a href=\"#ref-3\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-4\">15. 5. Technische Erkl\u00e4rung der A-bewerteten Dezibel, die bei L\u00e4rmmessungen verwendet werden. <a href=\"#ref-4\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-5\">5. Technical explanation of A-weighted decibels used in noise testing. <a href=\"#ref-5\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-6\">6. ISO 3744-Standard zur Messung von Luftschall. <a href=\"#ref-6\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-7\">7. EU-Richtlinie zur Regelung der L\u00e4rmbelastung am Arbeitsplatz. <a href=\"#ref-7\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-8\">8. OSHA-Vorschriften zur Definition von L\u00e4rmbelastung und Sicherheitsschwellenwerten. <a href=\"#ref-8\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-9\">9. WHO-Richtlinien f\u00fcr Umwelt- und Arbeitsl\u00e4rm. <a href=\"#ref-9\">\ufe0e<\/a><\/span><br \/>\n<span id=\"footnote-10\">10. HSE UK Leitfaden f\u00fcr bew\u00e4hrte Praktiken zur L\u00e4rmschutz am Arbeitsplatz. <a href=\"#ref-10\">\ufe0e<\/a><\/span>  <\/p>","protected":false},"excerpt":{"rendered":"<p>As the manufacturer, I often receive questions about whether shockwave therapy devices are \u201ctoo loud\u201d for clinical use. Our testing confirms that while the acoustic impulse is distinct, the sound exposure remains within recognized occupational safety limits when operated as directed. Shockwave therapy machines typically produce impulse noise between 75 dB and 90 dB, depending [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":8385,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[60],"tags":[],"class_list":["post-8380","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-shockwave-therapy-machine"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What is the decibel noise level of the Shockwave Therapy Machine? - KMSLaser<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kmslaser.com\/de\/wie-hoch-ist-der-dezibel-larmpegel-des-stoswellentherapiegerats\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is the decibel noise level of the Shockwave Therapy Machine?\" \/>\n<meta property=\"og:description\" content=\"As the manufacturer, I often receive questions about whether shockwave therapy devices are \u201ctoo loud\u201d for clinical use. Our testing confirms that while the acoustic impulse is distinct, the sound exposure remains within recognized occupational safety limits when operated as directed. Shockwave therapy machines typically produce impulse noise between 75 dB and 90 dB, depending [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kmslaser.com\/de\/wie-hoch-ist-der-dezibel-larmpegel-des-stoswellentherapiegerats\/\" \/>\n<meta property=\"og:site_name\" content=\"KMSLaser\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-18T23:14:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2a-realistic-treatment-room-scene-showing-a-patient.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sophia Wu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sophia Wu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Wie hoch ist der Dezibel-L\u00e4rmpegel der Sto\u00dfwellentherapiemaschine? - KMSLaser","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kmslaser.com\/de\/wie-hoch-ist-der-dezibel-larmpegel-des-stoswellentherapiegerats\/","og_locale":"de_DE","og_type":"article","og_title":"What is the decibel noise level of the Shockwave Therapy Machine?","og_description":"As the manufacturer, I often receive questions about whether shockwave therapy devices are \u201ctoo loud\u201d for clinical use. Our testing confirms that while the acoustic impulse is distinct, the sound exposure remains within recognized occupational safety limits when operated as directed. Shockwave therapy machines typically produce impulse noise between 75 dB and 90 dB, depending [&hellip;]","og_url":"https:\/\/kmslaser.com\/de\/wie-hoch-ist-der-dezibel-larmpegel-des-stoswellentherapiegerats\/","og_site_name":"KMSLaser","article_published_time":"2025-11-18T23:14:27+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2a-realistic-treatment-room-scene-showing-a-patient.jpg","type":"image\/jpeg"}],"author":"Sophia Wu","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Sophia Wu","Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#article","isPartOf":{"@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/"},"author":{"name":"Sophia Wu","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588"},"headline":"What is the decibel noise level of the Shockwave Therapy Machine?","datePublished":"2025-11-18T23:14:27+00:00","mainEntityOfPage":{"@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/"},"wordCount":752,"commentCount":0,"publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"image":{"@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2a-realistic-treatment-room-scene-showing-a-patient.jpg","articleSection":["Shockwave Therapy Machine"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/","url":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/","name":"Wie hoch ist der Dezibel-L\u00e4rmpegel der Sto\u00dfwellentherapiemaschine? - KMSLaser","isPartOf":{"@id":"https:\/\/kmslaser.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#primaryimage"},"image":{"@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2a-realistic-treatment-room-scene-showing-a-patient.jpg","datePublished":"2025-11-18T23:14:27+00:00","breadcrumb":{"@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#primaryimage","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2a-realistic-treatment-room-scene-showing-a-patient.jpg","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2025\/11\/2a-realistic-treatment-room-scene-showing-a-patient.jpg","width":600,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/kmslaser.com\/what-is-the-decibel-noise-level-of-the-shockwave-therapy-machine\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/kmslaser.com\/"},{"@type":"ListItem","position":2,"name":"What is the decibel noise level of the Shockwave Therapy Machine?"}]},{"@type":"WebSite","@id":"https:\/\/kmslaser.com\/#website","url":"https:\/\/kmslaser.com\/","name":"KMSLaser","description":"","publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kmslaser.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/kmslaser.com\/#organization","name":"KMSLaser","url":"https:\/\/kmslaser.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","width":180,"height":71,"caption":"KMSLaser"},"image":{"@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588","name":"Sophia Wu","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","caption":"Sophia Wu"},"url":"https:\/\/kmslaser.com\/de\/author\/sophia\/"}]}},"_links":{"self":[{"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/posts\/8380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/comments?post=8380"}],"version-history":[{"count":0,"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/posts\/8380\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/media\/8385"}],"wp:attachment":[{"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/media?parent=8380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/categories?post=8380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kmslaser.com\/de\/wp-json\/wp\/v2\/tags?post=8380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}