{"id":9722,"date":"2026-02-12T18:54:54","date_gmt":"2026-02-12T18:54:54","guid":{"rendered":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/"},"modified":"2026-02-12T18:54:54","modified_gmt":"2026-02-12T18:54:54","slug":"%d9%83%d9%8a%d9%81%d9%8a%d8%a9-%d8%a7%d9%84%d8%aa%d8%ad%d9%82%d9%82-%d9%85%d9%86-%d8%a3%d8%b7%d9%88%d8%a7%d9%84-%d8%a3%d8%b3%d9%84%d8%a7%d9%83-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d8%a7%d9%84%d9%85","status":"publish","type":"post","link":"https:\/\/kmslaser.com\/ar\/how-verify-custom-power-cord-lengths-purchasing\/","title":{"rendered":"\u0643\u064a\u0641 \u062a\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0637\u0648\u0627\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0639\u0646\u062f \u0634\u0631\u0627\u0621 \u062c\u0647\u0627\u0632 \u0639\u0644\u0627\u062c \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0627\u0644\u0635\u062f\u0645\u064a\u0629\u061f"},"content":{"rendered":"<style>article img, .entry-content img, .post-content img, .wp-block-image img, figure img, p img {max-width:100% !important; height:auto !important;}figure { max-width:100%; }img.top-image-square {width:280px; height:280px; object-fit:cover;border-radius:12px; box-shadow:0 2px 12px rgba(0,0,0,0.10);}@media (max-width:600px) {img.top-image-square { width:100%; height:auto; max-height:300px; }p:has(> img.top-image-square) { float:none !important; margin:0 auto 15px auto !important; text-align:center; }}.claim { background-color:#fff4f4; border-left:4px solid #e63946; border-radius:10px; padding:20px 24px; margin:24px 0; font-family:system-ui,sans-serif; line-height:1.6; position:relative; box-shadow:0 2px 6px rgba(0,0,0,0.03); }.claim-true { background-color:#eafaf0; border-left-color:#2ecc71; }.claim-icon { display:inline-block; font-size:18px; color:#e63946; margin-right:10px; vertical-align:middle; }.claim-true .claim-icon { color:#2ecc71; }.claim-title { display:flex; align-items:center; font-weight:600; font-size:16px; color:#222; }.claim-label { margin-left:auto; font-size:12px; background-color:#e63946; color:#fff; padding:3px 10px; border-radius:12px; font-weight:bold; }.claim-true .claim-label { background-color:#2ecc71; }.claim-explanation { margin-top:8px; color:#555; font-size:15px; }.claim-pair { margin:32px 0; }<\/style>\n<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922419751-1.jpg\" alt=\"Verifying custom power cord lengths for a shockwave therapy machine purchase (ID#1)\" class=\"top-image-square\">\n<\/p>\n<p>Every year, our production team receives urgent calls from distributors who discover their power cords are too short for their clinic layouts <a href=\"https:\/\/en.wikipedia.org\/wiki\/American_wire_gauge\" target=\"_blank\" rel=\"noopener noreferrer\">wire gauge requirements<\/a> <sup id=\"ref-1\"><a href=\"#footnote-1\" class=\"footnote-ref\">1<\/a><\/sup>. This problem delays installations, frustrates end customers, and sometimes requires expensive re-orders. When your facility layout demands a non-standard cord length, getting the specification right the first time is critical.<\/p>\n<p><strong>To verify custom power cord lengths when purchasing a shockwave therapy machine, you must specify exact measurements in your purchase order, request pre-shipment inspection documentation, confirm compliance with safety standards like IEC 60601-1 and UL 817, and obtain detailed QC reports showing cord length, gauge, and certification status before shipment.<\/strong><\/p>\n<p>This guide walks you through each verification step. We will cover how to communicate your requirements clearly, what to inspect before shipping, how to ensure US safety compliance, and how to document everything properly in your supplier&#8217;s quality control report.<\/p>\n<h2>How do I specify the exact power cord length for my custom shockwave therapy machine order?<\/h2>\n<p>Many buyers assume their supplier understands what &quot;longer cord&quot; means. They send vague requests and receive cords that still do not fit their space. Our engineering team has seen orders delayed by weeks because of unclear specifications.<\/p>\n<p><strong>To specify exact power cord length, measure your installation distance from the wall outlet to the device placement area, add 20% extra for routing flexibility, and document this measurement in meters and feet in your written purchase agreement with wire gauge requirements included.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922422207-2.jpg\" alt=\"Specifying exact power cord length by measuring distance and adding routing flexibility (ID#2)\" title=\"Specifying Power Cord Length\"><\/p>\n<h3>Why Precise Measurements Matter<\/h3>\n<p>In our factory, we manufacture <a href=\"https:\/\/longestmedical.com\/shockwave-therapy-machine\/\" target=\"_blank\" rel=\"noopener noreferrer\">shockwave therapy machine<\/a> <sup id=\"ref-2\"><a href=\"#footnote-2\" class=\"footnote-ref\">2<\/a><\/sup>s that deliver energy levels from 0.01 to 0.55 mJ\/mm\u00b2. These devices draw significant power. A cord that is too long without proper gauge adjustment will experience <a href=\"https:\/\/en.wikipedia.org\/wiki\/Voltage_drop\" target=\"_blank\" rel=\"noopener noreferrer\">voltage drop<\/a> <sup id=\"ref-3\"><a href=\"#footnote-3\" class=\"footnote-ref\">3<\/a><\/sup>. A cord that is too short forces unsafe extension cord use.<\/p>\n<p>Before contacting any supplier, physically measure your space. Use a tape measure to trace the exact path the cord will travel. Consider obstacles like furniture, walls, and foot traffic areas. Write down this number in both metric and imperial units.<\/p>\n<h3>The Specification Checklist<\/h3>\n<p>When placing your order, include these details in writing:<\/p>\n<table>\n<thead>\n<tr>\n<th>Specification Item<\/th>\n<th>What to Include<\/th>\n<th>Why It Matters<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Total cord length<\/td>\n<td>Exact measurement in meters and feet<\/td>\n<td>Prevents miscommunication<\/td>\n<\/tr>\n<tr>\n<td>Wire gauge (AWG)<\/td>\n<td>Required gauge for the length<\/td>\n<td>Prevents voltage drop<\/td>\n<\/tr>\n<tr>\n<td>Plug type<\/td>\n<td>NEMA 5-15P, 6-15P, or hospital-grade<\/td>\n<td>Ensures outlet compatibility<\/td>\n<\/tr>\n<tr>\n<td>Certification<\/td>\n<td><a href=\"https:\/\/www.intertek.com\/standards\/ul-817\/\" target=\"_blank\" rel=\"noopener noreferrer\">UL 817<\/a> <sup id=\"ref-4\"><a href=\"#footnote-4\" class=\"footnote-ref\">4<\/a><\/sup>, CSA, <a href=\"https:\/\/www.intertek.com\/medical\/iec-60601-1\/\" target=\"_blank\" rel=\"noopener noreferrer\">IEC 60601-1<\/a> <sup id=\"ref-5\"><a href=\"#footnote-5\" class=\"footnote-ref\">5<\/a><\/sup><\/td>\n<td>Confirms safety compliance<\/td>\n<\/tr>\n<tr>\n<td>Grounding type<\/td>\n<td>Three-prong with ground integrity<\/td>\n<td>Prevents electrical shock<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Calculating the Right Wire Gauge<\/h3>\n<p>Longer cords need thicker wire to maintain safe voltage levels. Our engineers use this general guideline for shockwave machines drawing 400W or more:<\/p>\n<table>\n<thead>\n<tr>\n<th>Cord Length<\/th>\n<th>Minimum Wire Gauge (AWG)<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Up to 2 meters<\/td>\n<td>18 AWG<\/td>\n<td>Standard factory cord<\/td>\n<\/tr>\n<tr>\n<td>2-4 meters<\/td>\n<td>16 AWG<\/td>\n<td>Common custom request<\/td>\n<\/tr>\n<tr>\n<td>4-6 meters<\/td>\n<td>14 AWG<\/td>\n<td>Requires verification<\/td>\n<\/tr>\n<tr>\n<td>Over 6 meters<\/td>\n<td>12 AWG or thicker<\/td>\n<td>Engineering review needed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Always confirm the specific power draw of your machine model. Higher wattage devices need thicker wire at shorter lengths.<\/p>\n<h3>Put It in Writing<\/h3>\n<p>Verbal agreements create problems. Send your supplier a written purchase specification that includes:<\/p>\n<ul>\n<li>Exact cord length required<\/li>\n<li>Wire gauge specification<\/li>\n<li>Plug and receptacle type<\/li>\n<li>Required certifications<\/li>\n<li>Deadline for confirmation<\/li>\n<\/ul>\n<p>Request written confirmation that your supplier can meet these specifications before placing your order.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> Custom power cord specifications must be documented in writing before production begins <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Written specifications prevent miscommunication and provide legal protection if the delivered product does not match requirements.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> Any power cord length works as long as the plug fits the outlet <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">Excessive cord length without proper wire gauge causes voltage drop, which can damage the shockwave machine and create safety hazards.<\/div>\n<\/div>\n<\/div>\n<h2>What steps should I take to verify cord measurements during the factory&#39;s pre-shipment inspection?<\/h2>\n<p>Many US distributors rely solely on factory photos for quality verification. When cords arrive at their warehouse, they discover the length is wrong. By then, the shipment has already cleared customs and return costs are high.<\/p>\n<p><strong>During pre-shipment inspection, request your supplier to measure the power cord with a calibrated tape measure, photograph the measurement against a ruler or measuring tape, document the results in an inspection report, and send photos showing the full cord length laid out straight before packaging.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922423164-3.jpg\" alt=\"Verifying cord measurements during pre-shipment inspection using a calibrated tape measure (ID#3)\" title=\"Pre-shipment Cord Inspection\"><\/p>\n<h3>The Pre-Shipment Inspection Process<\/h3>\n<p>At our facility, we conduct pre-shipment inspections as standard practice for all custom orders. This inspection happens after production is complete but before the product is packaged and shipped. For power cords, the inspection must verify both length and quality.<\/p>\n<p>A proper inspection includes:<\/p>\n<ol>\n<li>Laying the cord completely straight on a flat surface<\/li>\n<li>Measuring from plug face to device connector<\/li>\n<li>Photographing the measurement clearly<\/li>\n<li>Testing electrical continuity<\/li>\n<li>Verifying grounding integrity<\/li>\n<li>Checking for physical defects<\/li>\n<\/ol>\n<h3>What to Request from Your Supplier<\/h3>\n<p>Send your supplier a written inspection request that specifies exactly what you need documented. Be specific about photograph requirements.<\/p>\n<table>\n<thead>\n<tr>\n<th>Inspection Item<\/th>\n<th>Documentation Required<\/th>\n<th>Acceptance Criteria<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cord length<\/td>\n<td>Photo with measuring tape<\/td>\n<td>Within \u00b15cm of specification<\/td>\n<\/tr>\n<tr>\n<td>Wire gauge<\/td>\n<td>Label photo or test report<\/td>\n<td>Matches purchase order<\/td>\n<\/tr>\n<tr>\n<td>Plug type<\/td>\n<td>Close-up photo<\/td>\n<td>Correct configuration<\/td>\n<\/tr>\n<tr>\n<td>Ground continuity<\/td>\n<td>Test equipment reading<\/td>\n<td>Less than 0.1 ohm<\/td>\n<\/tr>\n<tr>\n<td>Physical condition<\/td>\n<td>Multiple angle photos<\/td>\n<td>No cuts, kinks, or damage<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Third-Party Inspection Option<\/h3>\n<p>For high-value orders, consider hiring a <a href=\"https:\/\/www.proqc.com\/services\/third-party-inspection\/\" target=\"_blank\" rel=\"noopener noreferrer\">third-party inspection company<\/a> <sup id=\"ref-6\"><a href=\"#footnote-6\" class=\"footnote-ref\">6<\/a><\/sup>. Companies like SGS, Bureau Veritas, or Intertek have offices in China and can conduct independent inspections. They will follow your specification checklist and provide an unbiased report.<\/p>\n<p>Third-party inspection costs typically range from $200 to $400 per inspection. This cost is small compared to the expense of receiving incorrect products.<\/p>\n<h3>Remote Inspection via Video Call<\/h3>\n<p>If third-party inspection is not feasible, request a live video call during the inspection. Watch the factory team measure the cord in real-time. This approach costs nothing and provides immediate verification.<\/p>\n<p>Ask your supplier to:<\/p>\n<ul>\n<li>Show the measuring tape calibration<\/li>\n<li>Demonstrate the measurement process<\/li>\n<li>Zoom in on the final reading<\/li>\n<li>Rotate the cord to show overall condition<\/li>\n<\/ul>\n<p>Document this call by recording it or taking screenshots with timestamps.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> Pre-shipment inspection photos must show the power cord measured against a calibrated measuring device <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Photos without a measuring reference cannot verify actual cord length and do not provide useful quality control documentation.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> Factory inspection photos are sufficient without measuring tape reference <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">Photos showing only the coiled cord provide no way to verify actual length and cannot catch measurement errors before shipping.<\/div>\n<\/div>\n<\/div>\n<h2>How can I ensure my custom cord length meets the safety standards required for my US distribution?<\/h2>\n<p>US distributors face serious liability if their <a href=\"https:\/\/www.fda.gov\/medical-devices\/overview-medical-devices\/what-medical-device\" target=\"_blank\" rel=\"noopener noreferrer\">medical devices<\/a> <sup id=\"ref-7\"><a href=\"#footnote-7\" class=\"footnote-ref\">7<\/a><\/sup> cause electrical injuries. Some buyers assume that any cord from China meets US standards. This assumption has resulted in FDA warnings, product recalls, and lawsuits.<\/p>\n<p><strong>To ensure US safety compliance, require your custom power cord to carry UL 817 listing for the cord set, hospital-grade certification with green dot marking for clinical use, and documentation proving compliance with IEC 60601-1 medical electrical equipment standards and FDA 21 CFR requirements.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922424025-4.jpg\" alt=\"Ensuring custom power cord compliance with UL 817 and hospital-grade safety standards (ID#4)\" title=\"US Safety Standards Compliance\"><\/p>\n<h3>Understanding US Safety Requirements<\/h3>\n<p>Shockwave therapy machines are classified as medical devices in the United States. The FDA regulates these products, and electrical safety standards are strict. Power cords for medical devices must meet higher standards than ordinary consumer electronics.<\/p>\n<p>The key standards for US distribution include:<\/p>\n<ul>\n<li><strong>IEC 60601-1<\/strong>: International standard for medical electrical equipment safety<\/li>\n<li><strong>UL 817<\/strong>: US standard for cord sets and power-supply cords<\/li>\n<li><strong>NFPA 99<\/strong>: Health Care Facilities Code for hospital installations<\/li>\n<li><strong>FDA 21 CFR<\/strong>: Federal regulations for medical device manufacturing<\/li>\n<\/ul>\n<h3>Hospital-Grade Requirements<\/h3>\n<p>For shockwave machines used in clinical settings, <a href=\"https:\/\/www.interpower.com\/resources\/articles\/north-american-hospital-grade-plug-requirements\/\" target=\"_blank\" rel=\"noopener noreferrer\">hospital-grade power cords<\/a> <sup id=\"ref-8\"><a href=\"#footnote-8\" class=\"footnote-ref\">8<\/a><\/sup> are essential. These cords must pass additional tests for:<\/p>\n<ul>\n<li>Blade retention (plug blades stay firmly connected)<\/li>\n<li>Ground continuity (grounding never fails)<\/li>\n<li>Assembly integrity (cord withstands repeated use)<\/li>\n<li>Strain relief (cord resists pulling damage)<\/li>\n<\/ul>\n<p>Hospital-grade plugs in the US carry a green dot marking. This marking indicates the plug meets UL 498 hospital-grade requirements. Always request photographic documentation of this marking.<\/p>\n<h3>Certification Documentation Checklist<\/h3>\n<p>Request these documents from your supplier before shipment:<\/p>\n<table>\n<thead>\n<tr>\n<th>Document<\/th>\n<th>What It Proves<\/th>\n<th>Who Issues It<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>UL 817 certificate<\/td>\n<td>Cord meets US cord set standards<\/td>\n<td>UL (Underwriters Laboratories)<\/td>\n<\/tr>\n<tr>\n<td>Hospital-grade test report<\/td>\n<td>Meets enhanced reliability requirements<\/td>\n<td>Accredited testing lab<\/td>\n<\/tr>\n<tr>\n<td>IEC 60601-1 test report<\/td>\n<td>Medical device electrical safety<\/td>\n<td>CNAS or A2LA accredited lab<\/td>\n<\/tr>\n<tr>\n<td>Component certificates<\/td>\n<td>Individual wire and plug certifications<\/td>\n<td>Component manufacturers<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>The Voltage Drop Consideration<\/h3>\n<p>US standard voltage is 120V, which is lower than many other countries. This means voltage drop in longer cords affects US users more than users in 220V countries. A cord that performs adequately in Europe might cause problems in the US.<\/p>\n<p>When our engineers design custom cords for US distribution, we calculate voltage drop using this formula:<\/p>\n<p>Voltage Drop = (2 \u00d7 Length \u00d7 Current \u00d7 Resistance per foot) \/ 1000<\/p>\n<p>For a 400W shockwave machine at 120V, current draw is approximately 3.3 amps. At this load, a 5-meter cord with 16 AWG wire will drop about 2.5V. This is acceptable. But a 10-meter cord with the same wire gauge would drop 5V, which could affect machine performance.<\/p>\n<h3>Working with Compliant Manufacturers<\/h3>\n<p>Not all Chinese manufacturers understand US medical device requirements. When sourcing custom power cords, ask potential suppliers:<\/p>\n<ol>\n<li>Have you supplied hospital-grade cords to US medical device companies before?<\/li>\n<li>Can you provide reference contacts for US customers?<\/li>\n<li>Do you have UL 817 listing for your cord sets?<\/li>\n<li>Can your testing documentation be verified by a US lab?<\/li>\n<\/ol>\n<p>If a supplier cannot answer these questions confidently, consider finding a different source.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> Hospital-grade power cords for US clinical use must display a green dot certification marking <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">The green dot indicates the plug has passed UL 498 hospital-grade testing for enhanced reliability and safety in healthcare environments.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> Any three-prong grounded cord meets US hospital safety requirements <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">Standard three-prong cords do not meet the enhanced blade retention, ground continuity, and durability requirements of hospital-grade certification.<\/div>\n<\/div>\n<\/div>\n<h2>How do I confirm the cord quality and length are documented in my supplier&#39;s QC report?<\/h2>\n<p>Some suppliers provide QC reports that look professional but contain generic information. When problems arise later, these reports offer no useful evidence. Our quality team has developed specific documentation requirements that protect both manufacturer and buyer.<\/p>\n<p><strong>To confirm proper QC documentation, require your supplier&#39;s report to include serial number traceability, actual measured cord length with tolerance, wire gauge verification test results, certification document references, inspector signature with date, and photographic evidence of key checkpoints.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922424888-5.jpg\" alt=\"Confirming cord quality and length documentation in the supplier quality control report (ID#5)\" title=\"Supplier QC Report Documentation\"><\/p>\n<h3>Essential QC Report Elements<\/h3>\n<p>A proper QC report for custom power cords must be specific to your order. Generic reports that could apply to any product are worthless. The report should include:<\/p>\n<ul>\n<li><strong>Order reference number<\/strong>: Links the report to your specific purchase<\/li>\n<li><strong>Production date<\/strong>: Shows when the cord was manufactured<\/li>\n<li><strong>Inspection date<\/strong>: Confirms inspection happened before shipping<\/li>\n<li><strong>Inspector identification<\/strong>: Names the person responsible<\/li>\n<li><strong>Test equipment used<\/strong>: Lists calibrated measurement tools<\/li>\n<li><strong>Actual measurements<\/strong>: Shows real numbers, not just &quot;pass\/fail&quot;<\/li>\n<\/ul>\n<h3>The Traceability Chain<\/h3>\n<p>Quality documentation should create a complete traceability chain from raw materials to finished product. This chain protects you if problems arise later.<\/p>\n<table>\n<thead>\n<tr>\n<th>Document Level<\/th>\n<th>What It Contains<\/th>\n<th>Why You Need It<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Raw material certificate<\/td>\n<td>Wire manufacturer&#39;s test report<\/td>\n<td>Proves wire quality<\/td>\n<\/tr>\n<tr>\n<td>Component certificate<\/td>\n<td>Plug and connector certifications<\/td>\n<td>Proves component compliance<\/td>\n<\/tr>\n<tr>\n<td>Assembly inspection<\/td>\n<td>In-process quality checkpoints<\/td>\n<td>Shows production quality<\/td>\n<\/tr>\n<tr>\n<td>Final inspection<\/td>\n<td>Complete product verification<\/td>\n<td>Confirms finished spec<\/td>\n<\/tr>\n<tr>\n<td>Shipping documentation<\/td>\n<td>Packing list with serial numbers<\/td>\n<td>Links product to paperwork<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Requesting Photographic Evidence<\/h3>\n<p>Photos in QC reports must be specific and useful. Generic product photos do not prove anything about your specific order. Request photos that show:<\/p>\n<ol>\n<li>The serial number or batch number visible<\/li>\n<li>Measurement tools touching the product<\/li>\n<li>Test equipment displaying readings<\/li>\n<li>Certification labels and markings<\/li>\n<li>Packaging condition before sealing<\/li>\n<\/ol>\n<h3>Digital Documentation and Storage<\/h3>\n<p>Store all QC documentation digitally with proper organization. Create a folder structure that links:<\/p>\n<ul>\n<li>Purchase order number<\/li>\n<li>Supplier QC report<\/li>\n<li>Pre-shipment inspection photos<\/li>\n<li>Certification documents<\/li>\n<li>Shipping and customs paperwork<\/li>\n<\/ul>\n<p>This documentation may be needed for:<\/p>\n<ul>\n<li>FDA audit response<\/li>\n<li>Customer complaint investigation<\/li>\n<li>Warranty claim verification<\/li>\n<li>Insurance claim support<\/li>\n<li>Legal dispute resolution<\/li>\n<\/ul>\n<h3>Verifying Report Authenticity<\/h3>\n<p>Unfortunately, some suppliers provide falsified documentation. Protect yourself by:<\/p>\n<ul>\n<li>Requesting original certification documents, not copies<\/li>\n<li>Verifying certificate numbers with issuing organizations<\/li>\n<li>Conducting occasional unannounced factory visits<\/li>\n<li>Using third-party inspection services for critical orders<\/li>\n<li>Building long-term relationships with verified suppliers<\/li>\n<\/ul>\n<p>At our company, we provide complete documentation packages because we understand that US distributors face regulatory scrutiny. We welcome documentation verification requests because they demonstrate that our customers take quality seriously.<\/p>\n<h3>Setting Documentation Requirements in Your Contract<\/h3>\n<p>Include specific documentation requirements in your purchase contract. State that:<\/p>\n<ul>\n<li>QC reports must be provided before shipment<\/li>\n<li>Reports must include all items on your checklist<\/li>\n<li>Photographic evidence is required for key checkpoints<\/li>\n<li>Missing documentation is grounds for shipment delay<\/li>\n<li>Falsified documentation terminates the business relationship<\/li>\n<\/ul>\n<p>Clear contractual requirements give you leverage if suppliers try to ship without proper documentation.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> QC reports must include actual measured values, not just pass\/fail results <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Actual measurements allow verification that specifications were met and provide evidence for troubleshooting if problems occur later.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> A supplier&#8217;s standard QC report template is sufficient for custom orders <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">Generic templates often omit custom specification details and cannot prove that your specific requirements were verified during inspection.<\/div>\n<\/div>\n<\/div>\n<h2>Conclusion<\/h2>\n<p>Verifying custom power cord lengths requires clear communication, thorough inspection, proper certification, and complete documentation. By following these steps, you protect your investment, ensure patient safety, and maintain <a href=\"https:\/\/www.techtarget.com\/whatis\/definition\/regulatory-compliance\" target=\"_blank\" rel=\"noopener noreferrer\">regulatory compliance<\/a> <sup id=\"ref-9\"><a href=\"#footnote-9\" class=\"footnote-ref\">9<\/a><\/sup> for your US distribution business.<\/p>\n<h2>Footnotes<\/h2>\n<p><span id=\"footnote-1\"><br \/>\n1. Provides a comprehensive explanation of American Wire Gauge (AWG) and its relevance to electrical conductors. <a href=\"#ref-1\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-2\"><br \/>\n2. Comprehensive guide on shockwave therapy machines, their uses, and benefits. <a href=\"#ref-2\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-3\"><br \/>\n3. Explains the concept of voltage drop in electrical circuits and its implications. <a href=\"#ref-3\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-4\"><br \/>\n4. Intertek provides an overview of the UL 817 standard for cord sets and power-supply cords. <a href=\"#ref-4\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-5\"><br \/>\n5. Authoritative overview of the IEC 60601-1 standard for medical electrical equipment safety. <a href=\"#ref-5\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-6\"><br \/>\n6. Provides information on third-party inspection services, including pre-shipment inspections. <a href=\"#ref-6\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-7\"><br \/>\n7. Direct and authoritative definition of medical devices from the U.S. Food and Drug Administration (FDA). <a href=\"#ref-7\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-8\"><br \/>\n8. Provides detailed requirements for North American hospital-grade plugs, including UL 498 and green dot markings. <a href=\"#ref-8\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-9\"><br \/>\n9. Provides a clear definition and explanation of regulatory compliance in a business context. <a href=\"#ref-9\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"To verify custom power cord lengths when purchasing a shockwave therapy machine, you must specify exact measurements in your purchase order, request pre-shipment inspection documentation, confirm compliance with safety standards like IEC 60601-1 and UL 817, and obtain detailed QC reports showing cord length, gauge, and certification status before shipment.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How do I specify the exact power cord length for my custom shockwave therapy machine order?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"To specify exact power cord length, measure your installation distance from the wall outlet to the device placement area, add 20% extra for routing flexibility, and document this measurement in meters and feet in your written purchase agreement with wire gauge requirements included.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What steps should I take to verify cord measurements during the factory's pre-shipment inspection?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"During pre-shipment inspection, request your supplier to measure the power cord with a calibrated tape measure, photograph the measurement against a ruler or measuring tape, document the results in an inspection report, and send photos showing the full cord length laid out straight before packaging.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can I ensure my custom cord length meets the safety standards required for my US distribution?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"To ensure US safety compliance, require your custom power cord to carry UL 817 listing for the cord set, hospital-grade certification with green dot marking for clinical use, and documentation proving compliance with IEC 60601-1 medical electrical equipment standards and FDA 21 CFR requirements.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How do I confirm the cord quality and length are documented in my supplier's QC report?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"To confirm proper QC documentation, require your supplier's report to include serial number traceability, actual measured cord length with tolerance, wire gauge verification test results, certification document references, inspector signature with date, and photographic evidence of key checkpoints.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n[\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Custom power cord specifications must be documented in writing before production begins\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Any power cord length works as long as the plug fits the outlet\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Pre-shipment inspection photos must show the power cord measured against a calibrated measuring device\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Factory inspection photos are sufficient without measuring tape reference\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Hospital-grade power cords for US clinical use must display a green dot certification marking\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Any three-prong grounded cord meets US hospital safety requirements\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"QC reports must include actual measured values, not just pass\/fail results\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"A supplier's standard QC report template is sufficient for custom orders\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  }\n]\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0644\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0637\u0648\u0627\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0639\u0646\u062f \u0634\u0631\u0627\u0621 \u062c\u0647\u0627\u0632 \u0639\u0644\u0627\u062c \u0628\u0627\u0644\u0645\u0648\u062c\u0627\u062a \u0627\u0644\u0635\u062f\u0645\u064a\u0629\u060c \u064a\u062c\u0628 \u0639\u0644\u064a\u0643 \u062a\u062d\u062f\u064a\u062f \u0642\u064a\u0627\u0633\u0627\u062a \u062f\u0642\u064a\u0642\u0629 \u0641\u064a \u0637\u0644\u0628 \u0627\u0644\u0634\u0631\u0627\u0621 \u0627\u0644\u062e\u0627\u0635 \u0628\u0643\u060c \u0648\u0637\u0644\u0628 \u0627\u0644\u0634\u062d\u0646 \u0627\u0644\u0645\u0633\u0628\u0642\u2026<\/p>","protected":false},"author":3,"featured_media":9717,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[60],"tags":[],"class_list":["post-9722","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-shockwave-therapy-machine"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine? - KMSLaser<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kmslaser.com\/ar\/\u0643\u064a\u0641\u064a\u0629-\u0627\u0644\u062a\u062d\u0642\u0642-\u0645\u0646-\u0623\u0637\u0648\u0627\u0644-\u0623\u0633\u0644\u0627\u0643-\u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u0645\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine?\" \/>\n<meta property=\"og:description\" content=\"To verify custom power cord lengths when purchasing a shockwave therapy machine, you must specify exact measurements in your purchase order, request pre-ship...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kmslaser.com\/ar\/\u0643\u064a\u0641\u064a\u0629-\u0627\u0644\u062a\u062d\u0642\u0642-\u0645\u0646-\u0623\u0637\u0648\u0627\u0644-\u0623\u0633\u0644\u0627\u0643-\u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u0645\/\" \/>\n<meta property=\"og:site_name\" content=\"KMSLaser\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-12T18:54:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922419751-1.jpg\" \/>\n<meta name=\"author\" content=\"Sophia Wu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sophia Wu\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 \u062f\u0642\u064a\u0642\u0629\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/\"},\"author\":{\"name\":\"Sophia Wu\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\"},\"headline\":\"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine?\",\"datePublished\":\"2026-02-12T18:54:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/\"},\"wordCount\":2316,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/v2-article-1770922419751-1.jpg\",\"articleSection\":[\"Shockwave Therapy Machine\"],\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/\",\"name\":\"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine? - KMSLaser\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/v2-article-1770922419751-1.jpg\",\"datePublished\":\"2026-02-12T18:54:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/v2-article-1770922419751-1.jpg\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/v2-article-1770922419751-1.jpg\",\"width\":1200,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/how-verify-custom-power-cord-lengths-purchasing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/kmslaser.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#website\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"name\":\"KMSLaser\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/kmslaser.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#organization\",\"name\":\"KMSLaser\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/kmslaser.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/logo.png\",\"width\":180,\"height\":71,\"caption\":\"KMSLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/kmslaser.com\\\/#\\\/schema\\\/person\\\/c37fe1d989e6bd9dbe4f1f7b6cfa9588\",\"name\":\"Sophia Wu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g\",\"caption\":\"Sophia Wu\"},\"url\":\"https:\\\/\\\/kmslaser.com\\\/ar\\\/author\\\/sophia\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u0643\u064a\u0641 \u062a\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0637\u0648\u0627\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0639\u0646\u062f \u0634\u0631\u0627\u0621 \u062c\u0647\u0627\u0632 \u0639\u0644\u0627\u062c \u0628\u0627\u0644\u0635\u062f\u0645\u0627\u062a\u061f - KMSLaser","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kmslaser.com\/ar\/\u0643\u064a\u0641\u064a\u0629-\u0627\u0644\u062a\u062d\u0642\u0642-\u0645\u0646-\u0623\u0637\u0648\u0627\u0644-\u0623\u0633\u0644\u0627\u0643-\u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u0645\/","og_locale":"ar_AR","og_type":"article","og_title":"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine?","og_description":"To verify custom power cord lengths when purchasing a shockwave therapy machine, you must specify exact measurements in your purchase order, request pre-ship...","og_url":"https:\/\/kmslaser.com\/ar\/\u0643\u064a\u0641\u064a\u0629-\u0627\u0644\u062a\u062d\u0642\u0642-\u0645\u0646-\u0623\u0637\u0648\u0627\u0644-\u0623\u0633\u0644\u0627\u0643-\u0627\u0644\u0637\u0627\u0642\u0629-\u0627\u0644\u0645\/","og_site_name":"KMSLaser","article_published_time":"2026-02-12T18:54:54+00:00","og_image":[{"url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922419751-1.jpg","type":"","width":"","height":""}],"author":"Sophia Wu","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"Sophia Wu","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"12 \u062f\u0642\u064a\u0642\u0629"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#article","isPartOf":{"@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/"},"author":{"name":"Sophia Wu","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588"},"headline":"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine?","datePublished":"2026-02-12T18:54:54+00:00","mainEntityOfPage":{"@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/"},"wordCount":2316,"commentCount":0,"publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"image":{"@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922419751-1.jpg","articleSection":["Shockwave Therapy Machine"],"inLanguage":"ar","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/","url":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/","name":"\u0643\u064a\u0641 \u062a\u062a\u062d\u0642\u0642 \u0645\u0646 \u0623\u0637\u0648\u0627\u0644 \u0623\u0633\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0639\u0646\u062f \u0634\u0631\u0627\u0621 \u062c\u0647\u0627\u0632 \u0639\u0644\u0627\u062c \u0628\u0627\u0644\u0635\u062f\u0645\u0627\u062a\u061f - KMSLaser","isPartOf":{"@id":"https:\/\/kmslaser.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#primaryimage"},"image":{"@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#primaryimage"},"thumbnailUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922419751-1.jpg","datePublished":"2026-02-12T18:54:54+00:00","breadcrumb":{"@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#primaryimage","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922419751-1.jpg","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2026\/02\/v2-article-1770922419751-1.jpg","width":1200,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/kmslaser.com\/how-verify-custom-power-cord-lengths-purchasing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/kmslaser.com\/"},{"@type":"ListItem","position":2,"name":"How to Verify Custom Power Cord Lengths When Purchasing a Shockwave Therapy Machine?"}]},{"@type":"WebSite","@id":"https:\/\/kmslaser.com\/#website","url":"https:\/\/kmslaser.com\/","name":"KMSLaser","description":"","publisher":{"@id":"https:\/\/kmslaser.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kmslaser.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Organization","@id":"https:\/\/kmslaser.com\/#organization","name":"KMSLaser","url":"https:\/\/kmslaser.com\/","logo":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/","url":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","contentUrl":"https:\/\/kmslaser.com\/wp-content\/uploads\/2020\/02\/logo.png","width":180,"height":71,"caption":"KMSLaser"},"image":{"@id":"https:\/\/kmslaser.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kmslaser.com\/#\/schema\/person\/c37fe1d989e6bd9dbe4f1f7b6cfa9588","name":"\u0635\u0648\u0641\u064a\u0627 \u0648\u0648","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9ef0ccfb314c8803023560c97cab787692ab7de1e607e67d9eb308b91561b84?s=96&d=mm&r=g","caption":"Sophia Wu"},"url":"https:\/\/kmslaser.com\/ar\/author\/sophia\/"}]}},"_links":{"self":[{"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/posts\/9722","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/comments?post=9722"}],"version-history":[{"count":0,"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/posts\/9722\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/media\/9717"}],"wp:attachment":[{"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/media?parent=9722"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/categories?post=9722"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kmslaser.com\/ar\/wp-json\/wp\/v2\/tags?post=9722"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}